A new method for fixation of probes for transcranial Doppler ultrasound

被引:44
作者
Giller, CA [1 ]
Giller, AM [1 ]
机构
[1] UNIV TEXAS,SW MED CTR,DEPT RADIOL,DALLAS,TX 75235
关键词
D O I
10.1111/jon199772103
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Although monitoring of blood velocity in the cerebral arteries with transcranial Doppler ultrasound is standard practice, meth ods for fixation of the ultrasound probe to the skull continue to impose a technical challenge. This report describes a novel method of probe fixation in which an inexpensive polymer block is custom-made for each patient to hold the probe at a fixed angle. In addition to comfort and durability, its major advantage is that the polymer block prevents dislodgment of the probe from the intended angle by forces of gravity or by patient movement. Thirty-one temporal windows were monitored with this technique, with stable signals obtained in ail subjects despite aggressive movements. Disadvantages include the inability to insonate more than one vessel and the cost for each block. However, the method is quick, is relatively inexpensive, and provides significant advantages of probe stability.
引用
收藏
页码:103 / 105
页数:3
相关论文
共 9 条
[1]   CEREBRAL AUTO-REGULATION DYNAMICS IN HUMANS [J].
AASLID, R ;
LINDEGAARD, KF ;
SORTEBERG, W ;
NORNES, H .
STROKE, 1989, 20 (01) :45-52
[2]   NON-INVASIVE TRANSCRANIAL DOPPLER ULTRASOUND RECORDING OF FLOW VELOCITY IN BASAL CEREBRAL-ARTERIES [J].
AASLID, R ;
MARKWALDER, TM ;
NORNES, H .
JOURNAL OF NEUROSURGERY, 1982, 57 (06) :769-774
[3]   PREDICTION OF TOLERANCE TO CAROTID-ARTERY OCCLUSION USING TRANSCRANIAL DOPPLER ULTRASOUND [J].
GILLER, CA ;
MATHEWS, D ;
WALKER, B ;
PURDY, P ;
ROSELAND, AM .
JOURNAL OF NEUROSURGERY, 1994, 81 (01) :15-19
[4]   THE FREQUENCY-DEPENDENT BEHAVIOR OF CEREBRAL AUTOREGULATION [J].
GILLER, CA .
NEUROSURGERY, 1990, 27 (03) :362-368
[5]   IMPACT OF MICROEMBOLISM AND HEMODYNAMIC-CHANGES IN THE BRAIN DURING CAROTID ENDARTERECTOMY [J].
JANSEN, C ;
RAMOS, LMP ;
VANHEESEWIJK, JPM ;
MOLL, FL ;
VANGIJN, J ;
ACKERSTAFF, RGA .
STROKE, 1994, 25 (05) :992-997
[6]  
MARCUS HS, 1995, STROKE, V26, P1517
[7]   A PROBE-HOLDER FOR BILATERAL TRANSCRANIAL DOPPLER SONOGRAPHY [J].
MULLER, HR ;
MOLL, R .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1992, 18 (01) :105-108
[8]   NONINVASIVE ASSESSMENT OF CO-2-INDUCED CEREBRAL VASOMOTOR RESPONSE IN NORMAL INDIVIDUALS AND PATIENTS WITH INTERNAL CAROTID-ARTERY OCCLUSIONS [J].
RINGELSTEIN, EB ;
SIEVERS, C ;
ECKER, S ;
SCHNEIDER, PA ;
OTIS, SM .
STROKE, 1988, 19 (08) :963-969
[9]   A HEAD AND TRANSDUCER HOLDING TECHNIQUE FOR TCD MONITORING OF THE VERTEBROBASILAR CIRCULATION [J].
WOODTLI, M ;
MULLER, HR .
ULTRASCHALL IN DER MEDIZIN, 1994, 15 (06) :293-295