Direct determination of 10 trace metals in 50 μL samples of coastal seawater using desolvating micronebulization sector field ICP-MS

被引:90
作者
Field, MP [1 ]
Cullen, JT [1 ]
Sherrell, RM [1 ]
机构
[1] Rutgers State Univ, Inst Marine & Coastal Sci, New Brunswick, NJ 08901 USA
关键词
D O I
10.1039/a901693g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Understanding the trace metal marine geochemistry of temporally variable coastal systems requires intensive sampling programs with attendant analytical burdens. Most established techniques for multi-element trace metal determinations are slow, require a skilled chemist, and are not easily automated. Advances in sample introduction systems and ICP-MS instrumentation now provide marine chemists with the sensitivity and mass resolution necessary to determine many trace metals at natural concentrations in coastal seawater. A new method has been developed for the rapid (10 samples h(-1)) determination of V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Cd and Pb in diluted seawater, requiring just 50 mu L of seawater and no reagents other than pure nitric acid. A sensitivity of 800 000-1 200 000 cps ppb(-1) Sr-86 in a 10% sea water matrix is obtained when microconcentric desolvating nebulization is combined with a shielded torch and hot plasma high resolution ICP-MS. Analyses are standardized by a matrix-matched external calibration curve with variations in sensitivity corrected by normalizing to the natural internal standard Sr, a conservative ion in seawater. The method thus depends on mass bias stability for each analyte relative to Sr, which was examined as a function of forward power and matrix and found to be optimized at 1100-1350 W. Precision and accuracy are limited by appropriate correction for blanks, which derive mainly from the ICP-MS introduction system, and are equivalent to about 10% of typical coastal seawater concentrations for these metals. Preliminary evaluation of a new low-flow nebulizer (mu Flow, Elemental Scientific, Omaha, NE, USA) suggested lower blanks and compatibility with solutions high in total dissolved solids compared with standard microconcentric designs. Determination of dissolved concentrations in reference seawater (CASS-3) demonstrate very good agreement with certified values (within 95% confidence limit) and a precision of 3-12% (1 sigma) for all elements except Cr (15%). The utility of the method is demonstrated by the determination of spatial trends for these metals in a transect of seawater samples from shelf waters off southern New Jersey, USA. The new technique is sufficiently sensitive to determine some of these metals in open ocean seawater and, with minor modifications, should be applicable to a larger suite of analytes in a wide variety of natural waters.
引用
收藏
页码:1425 / 1431
页数:7
相关论文
共 37 条
  • [1] DETERMINATION OF TRACE-METALS IN SEAWATER BY GRAPHITE-FURNACE ATOMIC-ABSORPTION FOLLOWING ONLINE SEPARATION AND PRECONCENTRATION
    AZEREDO, LC
    STURGEON, RE
    CURTIUS, AJ
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (01) : 91 - 98
  • [2] DETERMINATION OF TRACE-METALS IN REFERENCE WATER STANDARDS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH ONLINE PRECONCENTRATION
    BEAUCHEMIN, D
    BERMAN, SS
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (17) : 1857 - 1862
  • [3] INTERCOMPARISON OF 5 METHODS FOR THE DETERMINATION OF TRACE-METALS IN SEA-WATER
    BONIFORTI, R
    FERRAROLI, R
    FRIGIERI, P
    HELTAI, D
    QUEIRAZZA, G
    [J]. ANALYTICA CHIMICA ACTA, 1984, 162 (AUG) : 33 - 46
  • [4] Boyle E.A., 1975, ADV CHEM SER, V147, P44
  • [5] ON THE DISTRIBUTION OF COPPER, NICKEL, AND CADMIUM IN THE SURFACE WATERS OF THE NORTH-ATLANTIC AND NORTH PACIFIC-OCEAN
    BOYLE, EA
    HUESTED, SS
    JONES, SP
    [J]. JOURNAL OF GEOPHYSICAL RESEARCH-OCEANS, 1981, 86 (NC9) : 8048 - 8066
  • [6] TRACE-METALS AND RADIUM IN THE GULF OF MEXICO - AN EVALUATION OF RIVER AND CONTINENTAL-SHELF SOURCES
    BOYLE, EA
    REID, DF
    HUESTED, SS
    HERING, J
    [J]. EARTH AND PLANETARY SCIENCE LETTERS, 1984, 69 (01) : 69 - 87
  • [7] Bruland K. W., 1983, Trace Metals in Sea Water. Proceedings of the NATO Advanced Research Institute, P395
  • [8] Bruland K. W., 1983, CHEM OCEANOGR, V8, P157, DOI DOI 10.1016/B978-0-12-588608-6.50009-2
  • [9] ANALYSIS OF SEAWATER FOR DISSOLVED CADMIUM, COPPER AND LEAD - AN INTERCOMPARISON OF VOLTAMMETRIC AND ATOMIC-ABSORPTION METHODS
    BRULAND, KW
    COALE, KH
    MART, L
    [J]. MARINE CHEMISTRY, 1985, 17 (04) : 285 - 300
  • [10] SAMPLING AND ANALYTICAL METHODS FOR THE DETERMINATION OF COPPER, CADMIUM, ZINC, AND NICKEL AT THE NANOGRAM PER LITER LEVEL IN SEA-WATER
    BRULAND, KW
    FRANKS, RP
    KNAUER, GA
    MARTIN, JH
    [J]. ANALYTICA CHIMICA ACTA, 1979, 105 (01) : 233 - 245