Home blood pressure monitoring - Current knowledge and directions for future research

被引:35
作者
Reims, H [1 ]
Fossum, E
Kjeldsen, SE
Julius, S
机构
[1] Ullevaal Univ Hosp, Dept Cardiol, NO-0407 Oslo, Norway
[2] Univ Michigan Hosp, Div Hypertens, Ann Arbor, MI 48109 USA
关键词
blood pressure determination; blood pressure monitors; home blood pressure monitoring; hypertension; methods; self care;
D O I
10.1080/080370501753400584
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Home blood pressure (BP) monitoring has become popular in clinical practice and several automated devices for home BP measurement are now recommendable. Home BP is generally lower than clinic BP, and similar to daytime ambulatory BP. Home BP measurement eliminates the white coat effect and provides a high number of readings, and it is considered more accurate and reproducible than clinic BP. It can improve the sensitivity and statistical power of clinical drug trials and may have a higher prognostic value than clinic BP. Home monitoring may improve compliance and BP control, and reduce costs of hypertension management. Diagnostic thresholds and treatment target values for home BP remain to be established by longitudinal studies. Until then, home BP monitoring is to be considered a supplement. However, high home BP may support or confirm the diagnosis made in the doctor's office, and low home BP may warrant ambulatory BP monitoring. During long-term follow-up, home BP monitoring provides an opportunity for close attention to BP levels and variations. The first international guidelines have established a consensus document with recommendations, including a proposal of preliminary diagnostic thresholds, but further research is needed to define the precise role of home BP monitoring in clinical practice.
引用
收藏
页码:271 / 287
页数:17
相关论文
共 145 条
[1]  
ABE H, 1987, J CLIN HYPERTENS, V3, P661
[2]  
[Anonymous], 1997, ARCH INTERN MED, V157, P2413, DOI [10.1001/archinte.1997.00440420033005, DOI 10.1001/ARCHINTE.1997.00440420033005]
[3]   AMBULATORY BLOOD-PRESSURE MONITORING AND BLOOD-PRESSURE SELF-MEASUREMENT IN THE DIAGNOSIS AND MANAGEMENT OF HYPERTENSION [J].
APPEL, LJ ;
STASON, WB .
ANNALS OF INTERNAL MEDICINE, 1993, 118 (11) :867-882
[4]   Guidelines for the use of self-blood pressure monitoring: a summary report of the first international consensus conference [J].
Asmar, R ;
Zanchetti, A .
JOURNAL OF HYPERTENSION, 2000, 18 (05) :493-508
[5]  
Association for the Advancement of Medical Instrumentation, 1993, ANSI AAMI SP, P40
[6]  
Ayman D, 1940, AM J MED SCI, V200, P462
[7]   ANEROID SPHYGMOMANOMETERS - AN ASSESSMENT OF ACCURACY AT A UNIVERSITY HOSPITAL AND CLINICS [J].
BAILEY, RH ;
KNAUS, VL ;
BAUER, JH .
ARCHIVES OF INTERNAL MEDICINE, 1991, 151 (07) :1409-1412
[8]   A REVIEW OF COMMON ERRORS IN THE INDIRECT MEASUREMENT OF BLOOD-PRESSURE - SPHYGMOMANOMETRY [J].
BAILEY, RH ;
BAUER, JH .
ARCHIVES OF INTERNAL MEDICINE, 1993, 153 (24) :2741-2748
[9]   BLOOD PRESSURES THAT FALL ON RECHECKING [J].
BEEVERS, DG .
BMJ-BRITISH MEDICAL JOURNAL, 1982, 284 (6309) :71-72
[10]   SEASONAL-VARIATION IN ARTERIAL BLOOD-PRESSURE [J].
BRENNAN, PJ ;
GREENBERG, G ;
MIALL, WE ;
THOMPSON, SG .
BMJ-BRITISH MEDICAL JOURNAL, 1982, 285 (6346) :919-923