Influence of chain end groups on the matrix-assisted laser desorption/ionization spectra of polymer blends

被引:25
作者
Alicata, R
Montaudo, G
Puglisi, C
Samperi, F
机构
[1] Univ Catania, Dipartimento Sci Chim, I-95125 Catania, Italy
[2] CNR, Ist Chim & Tecnol Mat Polimerici, I-95125 Catania, Italy
关键词
D O I
10.1002/rcm.573
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The positive ion matrix-assisted laser desorption/ionization (MALDI) spectrum of an equimolar blend of Nylon 6 (Ny6) and hydroxyl-terminated polybutyleneterephthalate (PBT) shows a surprisingly strong imbalance between the two components. Since the average molar masses and the polydispersions of the two polymers are comparable, it follows that the efficiency of MALDI is quite different for the two components of the blend. This finding prompted us to a more detailed study, and to synthesize Ny6 and PBT samples terminated with different end groups, in order to analyze their blends by MALDI. The negative ion MALDI spectra of the mixtures investigated show that PBT samples do not yield signals, so that only Ny6 peaks appear in these spectra. By comparing positive and negative ion MALDI spectra of mixtures of Ny6 terminated with various end groups, it was found that the peak intensity depends on the nature of the end groups. The results reported in the present study may help to clarify some fundamental aspects of the mechanisms of ion formation, when MALDI mass spectrometry is applied to macromolecules. End group ionization efficiency appears to be the most important parameter in determining the relative intensity of peaks in the MALDI spectra of the polymer blends investigated. End-group-dependent ionization is the key to the rationalization of the relative peak intensities in MALDI spectra of polymer mixtures. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:248 / 260
页数:13
相关论文
共 21 条
[1]  
ALICATA R, IN PRESS
[2]  
BRANDRUP J, 1989, POLYM HDB
[3]   The limitations of MALDI-TOF mass spectrometry in the analysis of wide polydisperse polymers [J].
Byrd, HCM ;
McEwen, CN .
ANALYTICAL CHEMISTRY, 2000, 72 (19) :4568-4576
[4]  
Garozzo D, 1995, RAPID COMMUN MASS SP, V9, P937
[5]  
Guo BC, 1997, RAPID COMMUN MASS SP, V11, P781, DOI 10.1002/(SICI)1097-0231(19970422)11:7<781::AID-RCM915>3.0.CO
[6]  
2-T
[7]   Comparison of most probable peak values as measured for polymer distributions by MALDI mass spectrometry and by size exclusion chromatography [J].
Jackson, C ;
Larsen, B ;
McEwen, C .
ANALYTICAL CHEMISTRY, 1996, 68 (08) :1303-1308
[8]  
LARSEN BS, 1999, POLYM PREPRINTS
[9]  
Martin K, 1996, RAPID COMMUN MASS SP, V10, P1471
[10]  
MCEWEN CN, 1998, P 46 ASMS C MASS SPE, P409