Comparison of coronary artery lesion length by NIRS-IVUS versus angiography alone

被引:15
作者
Hanson, Ivan D. [1 ]
Goldstein, James A. [1 ]
Dixon, Simon R. [1 ]
Stone, Gregg W. [2 ,3 ]
机构
[1] Beaumont Hlth Syst, Royal Oak, MI 48073 USA
[2] Columbia Univ, Med Ctr, New York, NY USA
[3] Columbia Univ, Cardiovasc Res Fdn, New York, NY USA
关键词
intravascular ultrasound; lipid-core plaque; near-infrared spectroscopy; plaque burden; stent; NEAR-INFRARED-SPECTROSCOPY; ELUTING STENT IMPLANTATION; INTRAVASCULAR ULTRASOUND ASSESSMENT; LIPID-CORE PLAQUES; THROMBOSIS; RESTENOSIS; EDGE; PREDICTORS; TRIAL; RISK;
D O I
10.1097/MCA.0000000000000263
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
BackgroundIntravascular ultrasound (IVUS) studies analyzing target lesion plaque burden (PB) have established that invasive coronary angiography commonly underestimates lesion length, predisposing to geographic miss' during a percutaneous coronary intervention, which has been associated with adverse outcomes. Plaque composition may also influence stent outcome. The present study used near-infrared spectroscopy and IVUS (NIRS-IVUS) to assess the prevalence of PB and lipid-core plaque (LCP) extending beyond angiographic borders of target lesions.MethodsFifty-eight patients (58 lesions) undergoing NIRS-IVUS were identified. By invasive coronary angiography, target lesion length and minimum lumen diameter were measured. Plaque, defined as NIRS-IVUS atheroma (either PB>40% or LCP), was identified adjacent to the angiographic-defined lesion margins.ResultsBy NIRS-IVUS, atheroma (either PB>40% or LCP) was identified beyond angiographic lesion margins in 52/58 (90%) lesions. The mean lesion length was 13.45.9mm by angiography and 19.8 +/- 7.0mm (P<0.0001) by NIRS-IVUS. LCP extending beyond the angiographic border was observed in 30/58 (52%) lesions.ConclusionNIRS-IVUS imaging shows that target lesion length is commonly underestimated by angiography alone. This finding may have implications for stent length selection and avoidance of geographic miss.
引用
收藏
页码:484 / 489
页数:6
相关论文
共 23 条
[1]
Impact of stent deployment procedural factors on long-term effectiveness and safety of sirolimus-eluting stents (final results of the multicenter prospective STLLR trial) [J].
Costa, Marco A. ;
Angiolillo, Dominick J. ;
Tannenbaum, Mark ;
Driesman, Mitchell ;
Chu, Alan ;
Patterson, John ;
Kuehl, William ;
Battaglia, Joseph ;
Dabbons, Samir ;
Shamoon, Fayez ;
Flieshman, Bruce ;
Niederman, Alan ;
Bass, Theodore A. .
AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (12) :1704-1711
[2]
Implications of the presence and length of "geographic miss" on restenosis and the edge phenomenon in the INHIBIT trial [J].
Costantini, CO ;
Lansky, AJ ;
Mintz, FS ;
Shirai, K ;
Teirstein, PS ;
Stone, G ;
Vandertie, L ;
Proctor, B ;
Fahy, M ;
Yeung, A ;
Raizner, AE ;
Waksman, R ;
Leon, MB .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (10) :1261-1265
[3]
Analysis of Target Lesion Length Before Coronary Artery Stenting Using Angiography and Near-Infrared Spectroscopy Versus Angiography Alone [J].
Dixon, Simon R. ;
Grines, Cindy L. ;
Munir, Ahmad ;
Madder, Ryan D. ;
Safian, Robert D. ;
Hanzel, George S. ;
Pica, Mark C. ;
Goldstein, James A. .
AMERICAN JOURNAL OF CARDIOLOGY, 2012, 109 (01) :60-66
[4]
Fitzgerald PJ, 2000, CIRCULATION, V102, P523
[5]
Detection of Lipid Core Coronary Plaques in Autopsy Specimens With a Novel Catheter-Based Near-Infrared Spectroscopy System [J].
Gardner, Craig M. ;
Tan, Huwei ;
Hull, Edward L. ;
Lisauskas, Jennifer B. ;
Sum, Stephen T. ;
Meese, Thomas M. ;
Jiang, Chunsheng ;
Madden, Sean P. ;
Caplan, Jay D. ;
Burke, Allen P. ;
Virmani, Renu ;
Goldstein, James ;
Muller, James E. .
JACC-CARDIOVASCULAR IMAGING, 2008, 1 (05) :638-648
[6]
Detection of Lipid-Core Plaques by Intracoronary Near-Infrared Spectroscopy Identifies High Risk of Periprocedural Myocardial Infarction [J].
Goldstein, James A. ;
Maini, Brijeshwar ;
Dixon, Simon R. ;
Brilakis, Emmanouil S. ;
Grines, Cindy L. ;
Rizik, David G. ;
Powers, Eric R. ;
Steinberg, Daniel H. ;
Shunk, Kendrick A. ;
Weisz, Giora ;
Moreno, Pedro R. ;
Kini, Annapoorna ;
Sharma, Samin K. ;
Hendricks, Michael J. ;
Sum, Steve T. ;
Madden, Sean P. ;
Muller, James E. ;
Stone, Gregg W. ;
Kern, Morton J. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (05) :429-437
[7]
Coronary Embolization Following Balloon Dilation of Lipid-Core Plaques [J].
Goldstein, James A. ;
Grines, Cindy ;
Fischell, Tim ;
Virmani, Renu ;
Rizik, David ;
Muller, James ;
Dixon, Simon R. .
JACC-CARDIOVASCULAR IMAGING, 2009, 2 (12) :1420-1424
[8]
Clinical, angiographic, and procedural predictors of angiographic restenosis after sirolimus-eluting stent implantation in complex patients - An evaluation from the Rapamycin-Eluting Stent evaluated at Rotterdam Cardiology Hospital (RESEARCH) study [J].
Lemos, PA ;
Hoye, A ;
Goedhart, D ;
Arampatzis, CA ;
Saia, F ;
van der Giessen, WJ ;
McFadden, E ;
Sianos, G ;
Smits, PC ;
Hofma, SH ;
de Feyter, PJ ;
van Domburg, RT ;
Serruys, PW .
CIRCULATION, 2004, 109 (11) :1366-1370
[9]
Intravascular Ultrasound Assessment of the Incidence and Predictors of Edge Dissections After Drug-Eluting Stent Implantation [J].
Liu, Xuebo ;
Tsujita, Kenichi ;
Maehara, Akiko ;
Mintz, Gary S. ;
Weisz, Giora ;
Dangas, George D. ;
Lansky, Alexandra J. ;
Kreps, Edward M. ;
Rabbani, LeRoy E. ;
Collins, Michael ;
Stone, Gregg W. ;
Moses, Jeffrey W. ;
Mehran, Roxana ;
Leon, Martin B. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (10) :997-1004
[10]
A Volumetric Intravascular Ultrasound Comparison of Early Drug-Eluting Stent Thrombosis Versus Restenosis [J].
Liu, Xuebo ;
Doi, Hiroshi ;
Maehara, Akiko ;
Mintz, Gary S. ;
Costa, Jose de Ribamar, Jr. ;
Sano, Koichi ;
Weisz, Giora ;
Dangas, George D. ;
Lansky, Alexandra J. ;
Kreps, Edward M. ;
Collins, Michael ;
Fahy, Martin ;
Stone, Gregg W. ;
Moses, Jeffrey W. ;
Leon, Martin B. ;
Mehran, Roxana .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (05) :428-434