Artificial neural network analysis of teachers' performance against thermal comfort

被引:5
作者
Alzahrani, Hamdan [1 ]
Arif, Mohammed [1 ]
Kaushik, Amit [1 ]
Goulding, Jack [1 ]
Heesom, David [1 ]
机构
[1] Univ Wolverhampton, Fac Sci & Engn, Sch Architecture & Bldg Environm, Wolverhampton, England
关键词
Thermal comfort; Artificial neural network; Indoor environment quality; Teacher's performance; INDOOR AIR-QUALITY; ENVIRONMENTAL-QUALITY; ENERGY PERFORMANCE; PRODUCTIVITY; POSTOCCUPANCY; TEMPERATURE; BUILDINGS; SENSATION; POLLUTION; MODEL;
D O I
10.1108/IJBPA-11-2019-0098
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Purpose The impact of thermal comfort in educational buildings continues to be of major importance in both the design and construction phases. Given this, it is also equally important to understand and appreciate the impact of design decisions on post-occupancy performance, particularly on staff and students. This study aims to present the effect of IEQ on teachers' performance. This study would provide thermal environment requirements to BIM-led school refurbishment projects. Design/methodology/approach This paper presents a detailed investigation into the direct impact of thermal parameters (temperature, relative humidity and ventilation rates) on teacher performance. In doing so, the research methodological approach combines explicit mixed-methods using questionnaire surveys and physical measurements of thermal parameters to identify correlation and inference. This was conducted through a single case study using a technical college based in Saudi Arabia. Findings Findings from this work were used to develop a model using an artificial neural network (ANN) to establish causal relationships. Research findings indicate an optimal temperature range between 23 and 25 degrees C, with a 65% relative humidity and 0.4 m/s ventilation rate. This ratio delivered optimum results for both comfort and performance. Originality/value This paper presents a unique investigation into the effect of thermal comfort on teacher performance in Saudi Arabia using ANN to conduct data analysis that produced indoor environmental quality optimal temperature and relative humidity range.
引用
收藏
页码:20 / 32
页数:13
相关论文
共 63 条
[1]   Post-occupancy studies of an office environment: Energy performance and occupants' satisfaction [J].
Agha-Hossein, M. M. ;
El-Jouzi, S. ;
Elmualim, A. A. ;
Ellis, J. ;
Williams, M. .
BUILDING AND ENVIRONMENT, 2013, 69 :121-130
[2]   Thermal comfort and productivity - Evaluation of workplace environment in a task conditioned office [J].
Akimoto, Takashi ;
Tanabe, Shin-ichi ;
Yanai, Takashi ;
Sasaki, Masato .
BUILDING AND ENVIRONMENT, 2010, 45 (01) :45-50
[3]  
Al horr Yousef, 2016, International Journal of Sustainable Built Environment, V5, P1, DOI 10.1016/j.ijsbe.2016.03.006
[4]   Occupant productivity and office indoor environment quality: A review of the literature [J].
Al Horr, Yousef ;
Arif, Mohammed ;
Kaushik, Amit ;
Mazroei, Ahmed ;
Katafygiotou, Martha ;
Elsarrag, Esam .
BUILDING AND ENVIRONMENT, 2016, 105 :369-389
[5]   Survey of occupant behaviour and control of indoor environment in Danish dwellings [J].
Andersen, Rune Vinther ;
Toftum, Jorn ;
Andersen, Klaus Kaae ;
Olesen, Bjarne W. .
ENERGY AND BUILDINGS, 2009, 41 (01) :11-16
[6]  
[Anonymous], 2002, WORKER PERFORMANCE V
[7]  
ASHRAE, 2004, 552020 ASHRAE
[8]  
Awang N.A., 2015, J BUILD PERFORM SIMU, V6, P105
[9]  
Azhar S., 2009, Int. J. Constr. Educ. Res, V5, P276, DOI DOI 10.1080/15578770903355657
[10]   Effects of pollution from personal computers on perceived air quality, SBS symptoms and productivity in offices [J].
Bakó-Biró, Z ;
Wargocki, P ;
Weschler, CJ ;
Fanger, PO .
INDOOR AIR, 2004, 14 (03) :178-187