Measurement of enzyme activity in single cells by voltammetry using a microcell with a positionable dual electrode

被引:26
作者
Gao, H [1 ]
Zhao, MH [1 ]
Zhang, XL [1 ]
Jin, WR [1 ]
机构
[1] Shandong Univ, Sch Chem & Chem Engn, Jinan 250100, Peoples R China
关键词
D O I
10.1021/ac051178c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical single-cell analysis for enzyme activity was developed using microcells on a microcell array coupled with a positionable dual microelectrode. The microcell array with the nanoliter-scale microcells was constructed using simple chemical etching without photolithographic techniques. The positionable dual microelectrodes consisted of the nanometer-to-micrometer-radius Au disk working electrode and a similar to 80-mu m-radius Ag/AgCl reference electrode. Peroxidase was chosen as the model enzyme. Factors that concern electrochemical single-cell analysis in microcells such as solution evaporation, interference of soluble oxygen, electrode size, solution volume, and electrode fouling were investigated and discussed. The 20 or 100 nL of detection volume was found to be suitable for peroxidase determination in single neutrophils or single acute promyelocytic leukemia cells without interference from intracellular macromolecules and electrode fouling, when the dual electrode with a 10-mu m-radius An disk working electrode was used. Cells were perforated with digitonin before transferring them into the microcells, to lyse cells easily. The perforated cells were transferred into the microcells by pushing a microscope slide on a drop of the cell suspension on the microcell array. After a single cell in the microcell was lysed using a freeze-thawing technique and allowed to dry, physiological buffer saline containing 2.0 x 10(-3) mol/L hydroquinone and 2.0 x 10(-3) mol/L H2O2 as the substrates of the enzyme-catalyzed reaction was added. The microcell array was positioned in a constant-humidity chamber to prevent evaporation. Then the dual electrode was inserted into the microcell by means of a scanning electrochemical microscope and the product benzoquinone of the enzyme-catalyzed reaction was voltammetrically detected. Peroxidase activity could be quantified using the steady-state current on the voltammogram after subtracting the blank and using the calibration curve.
引用
收藏
页码:231 / 238
页数:8
相关论文
共 70 条
[1]   INTRACELLULAR ANALYSIS WITH AN IMMOBILIZED-ENZYME GLUCOSE ELECTRODE HAVING A 2-MU-M DIAMETER AND SUBSECOND RESPONSE-TIMES [J].
ABE, T ;
LAU, YY ;
EWING, AG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (19) :7421-7423
[2]  
Amatore C, 2001, CHEM-EUR J, V7, P4171, DOI 10.1002/1521-3765(20011001)7:19<4171::AID-CHEM4171>3.0.CO
[3]  
2-5
[4]   Analysis of individual biochemical events based on artificial synapses using ultramicroelectrodes: cellular oxidative burst [J].
Amatore, C ;
Arbault, S ;
Bruce, D ;
de Oliveira, P ;
Erard, M ;
Vuillaume, M .
FARADAY DISCUSSIONS, 2000, 116 :319-333
[5]   MONITORING AN OXIDATIVE STRESS MECHANISM AT A SINGLE HUMAN FIBROBLAST [J].
ARBAULT, S ;
PANTANO, P ;
JANKOWSKI, JA ;
VUILLAUME, M ;
AMATORE, C .
ANALYTICAL CHEMISTRY, 1995, 67 (19) :3382-3390
[6]   Electrochemistry in nanovials fabricated by combining screen printing and laser micromachining [J].
Ball, JC ;
Scott, DL ;
Lumpp, JK ;
Daunert, S ;
Wang, J ;
Bachas, LG .
ANALYTICAL CHEMISTRY, 2000, 72 (03) :497-501
[7]   SCANNING ELECTROCHEMICAL MICROSCOPY - INTRODUCTION AND PRINCIPLES [J].
BARD, AJ ;
FAN, FRF ;
KWAK, J ;
LEV, O .
ANALYTICAL CHEMISTRY, 1989, 61 (02) :132-138
[8]   ELECTROCHEMICAL MEASUREMENTS IN SUBMICROLITER VOLUMES [J].
BOWYER, WJ ;
CLARK, ME ;
INGRAM, JL .
ANALYTICAL CHEMISTRY, 1992, 64 (04) :459-462
[9]   Single cell measurements of purine release using a micromachined electroanalytical sensor [J].
Bratten, CDT ;
Cobbold, PH ;
Cooper, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (06) :1164-1170
[10]   Micromachining sensors for electrochemical measurement in subnanoliter volumes [J].
Bratten, CDT ;
Cobbold, PH ;
Cooper, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :253-258