Identification of inorganic ions in post-blast explosive residues using portable CE instrumentation and capacitively coupled contactless conductivity detection

被引:81
作者
Hutchinson, Joseph P. [1 ]
Johns, Cameron [1 ]
Breadmore, Michael C. [1 ]
Hilder, Emily F. [1 ]
Guijt, Rosanne M. [1 ]
Lennard, Chris [2 ]
Dicinoski, Greg [1 ]
Haddad, Paul R. [1 ]
机构
[1] Univ Tasmania, Fac Sci Engn & Technol, Sch Chem, ACROSS, Hobart, Tas 7001, Australia
[2] Univ Canberra, Fac Sci, Natl Ctr Forens Studies, Canberra, ACT 2601, Australia
基金
澳大利亚研究理事会;
关键词
Contactless conductivity detection; Homemade explosive devices; Inorganic anions and cations; Portable CE; Post-blast residues;
D O I
10.1002/elps.200800226
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Novel CE methods have been developed on portable instrumentation adapted to accommodate a capacitively coupled contactless conductivity detector for the separation and sensitive detection of inorganic anions and cations in post-blast explosive residues from homemade inorganic explosive devices. The methods presented combine sensitivity and speed of analysis for the wide range of inorganic ions used in this study. Separate methods were employed for the separation of anions and cations. The anion separation method utilised a low conductivity 70 mM Tris/70 mM CHES aqueous electrolyte (pH 8.6) with a 90 cm capillary coated with hexadimethrine bromide to reverse the EOF. Fifteen anions could be baseline separated in 7 min with detection limits in the range 27-240 mu g/L. A selection of ten anions deemed most important in this application could be separated in 45 s on a shorter capillary (30.6 cm) using the same electrolyte. The cation separation method was performed on a 73 cm. length of fused-silica capillary using an electrolyte system composed of 10 mM histidine and 50 mM acetic acid, at pH 4.2. The addition of the complexants, 1 mM hydroxyisobutyric acid and 0.7 mM 18-crown-6 ether, enhanced selectivity and allowed the separation of eleven inorganic cations in under 7 min with detection limits in the range 31-240 mu g/L. The developed methods were successfully field tested on post-blast residues obtained from the controlled detonation of homemade explosive devices. Results were verified using ion chromatographic analyses of the same samples.
引用
收藏
页码:4593 / 4602
页数:10
相关论文
共 42 条
[2]   Application of capillary isotachophoresis and capillary zone electrophoresis to the determination of inorganic ions in food and feed samples [J].
Blatny, P ;
Kvasnicka, F .
JOURNAL OF CHROMATOGRAPHY A, 1999, 834 (1-2) :419-431
[3]   Flow injection methods of analysis for waters. I. Inorganic species [J].
Danet, AF ;
Cheregi, M ;
Calatayud, JM ;
Mateo, JVG ;
Enein, HYA .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2001, 31 (03) :191-222
[4]  
Dean J.A., 2001, Lange's Handbook of Chemistry, V15
[5]   Determination of inorganic ions using microfluidic devices [J].
Evenhuis, CJ ;
Guijt, RM ;
Macka, M ;
Haddad, PR .
ELECTROPHORESIS, 2004, 25 (21-22) :3602-3624
[6]   Application of capillary electrophoresis to the analysis of inorganic ions in environmental samples [J].
Fukushi, K ;
Takeda, S ;
Chayama, K ;
Wakida, S .
JOURNAL OF CHROMATOGRAPHY A, 1999, 834 (1-2) :349-362
[7]  
Harris D. C., 1995, QUANTITATIVE CHEM AN
[8]   A novel method for analysis of explosives residue by simultaneous detection of anions and cations via capillary zone electrophoresis [J].
Hopper, KG ;
LeClair, H ;
McCord, BR .
TALANTA, 2005, 67 (02) :304-312
[9]  
HULANICKI A, 1979, ION SELECTIVE ELECTR, V1, P207
[10]   Identification of inorganic improvised explosive devices by analysis of postblast residues using portable capillary electrophoresis instrumentation and indirect photometric detection with a light-emitting diode [J].
Hutchinson, Joseph P. ;
Evenhuis, Christopher J. ;
Johns, Cameron ;
Kazarian, Artaches A. ;
Breadmore, Michael C. ;
Macka, Miroslav ;
Hilder, Emily F. ;
Guijt, Rosanne M. ;
Dicinoski, Greg W. ;
Haddad, Paul R. .
ANALYTICAL CHEMISTRY, 2007, 79 (18) :7005-7013