Clinical evaluation of PET image reconstruction using a spatial resolution model

被引:44
作者
Andersen, Flemming Littrup [1 ]
Klausen, Thomas Levin [1 ]
Loft, Annika [1 ]
Beyer, Thomas [1 ,2 ]
Holm, Soren [1 ]
机构
[1] Copenhagen Univ Hosp, Rigshosp, Dept Clin Physiol Nucl Med & PET, Copenhagen, Denmark
[2] Cmi Experts GmbH, Zurich, Switzerland
关键词
Positron emission tomography; PET/CT; Spatial resolution; Point spread function; Image reconstruction; VARIANT SYSTEM MODEL; SCANNER;
D O I
10.1016/j.ejrad.2012.11.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: PET image resolution is variable across the measured field-of-view and described by the point spread function (PSF). When accounting for the PSF during PET image reconstruction image resolution is improved and partial volume effects are reduced. Here, we evaluate the effect of PSF-based reconstruction on lesion quantification in routine clinical whole-body (WB) PET/CT imaging. Materials and methods: 41 oncology patients were referred for a WB-PET/CT examination (Biograph 40 TruePoint). Emission data were acquired at 2.5 min/bed at 1 h pi of 400 MBq [18F]-FDG. Attenuation-corrected PET images were reconstructed on 336 x 336-matrices using: (R1) standard AW-OSEM (4 iter, 8 subsets, 4 mm Gaussian) and (R2) AW-OSEM with PSF (3 iter, 21 subsets, 2 mm). Blinded and randomised reading of R1- and R2-PET images was performed. Individual lesions were located and counted independently on both sets of images. The relative change in PET quantification (SUVmax, SUVmean, volume) of lesions seen on R1 and R2 is reported as (R2 - R1)/R1. Furthermore, SUVmax and SUVmean was measured for a 3 cm spherical norm region in the right lobe of the healthy liver for R1 and R2. Results: Clinical reading revealed 91 and 103 positive lesions for R1 and R2, respectively. For all lesions SUVmax (R2) was higher than SUVmax (R1). Regression analysis indicated that the relative increase in SUVmax (and SUVmean) decreased with lesion size, whilst it increased with increasing radial distance from the centre of the field of view (FOV). There was no significant difference in SUVmean in homogenous liver tissue between R1 and R2. Conclusion: In whole-body FDG-PET/CT using routine clinical protocols, PSF-based PET reconstruction increases lesion detection and affects SUVmax measurements compared to standard AW-OSEM PET reconstruction. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:862 / 869
页数:8
相关论文
共 28 条
[1]
Application and Evaluation of a Measured Spatially Variant System Model for PET Image Reconstruction [J].
Alessio, Adam M. ;
Stearns, Charles W. ;
Tong, Shan ;
Ross, Steven G. ;
Kohlmyer, Steve ;
Ganin, Alex ;
Kinahan, Paul E. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (03) :938-949
[2]
Application of a spatially variant system model for 3-D whole-body pet image reconstruction [J].
Alessio, Adam M. ;
Kinahan, Paul E. .
2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, :1315-1318
[3]
Bendriem B., 1998, THEORY PRACTICE 3D P, DOI DOI 10.1007/978-94-017-3475-2
[4]
Theragnostic imaging for radiation oncology: dose-painting by numbers [J].
Bentzen, SM .
LANCET ONCOLOGY, 2005, 6 (02) :112-117
[5]
Physical Performance of the new hybrid PET/CT Discovery-690 [J].
Bettinardi, V. ;
Presotto, L. ;
Rapisarda, E. ;
Picchio, M. ;
Gianolli, L. ;
Gilardi, M. C. .
MEDICAL PHYSICS, 2011, 38 (10) :5394-5411
[6]
Beyer T, 2000, J NUCL MED, V41, P1369
[7]
Mutatis Mutandis: Harmonize the Standard! [J].
Boellaard, Ronald .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (01) :1-3
[8]
FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0 [J].
Boellaard, Ronald ;
O'Doherty, Mike J. ;
Weber, Wolfgang A. ;
Mottaghy, Felix M. ;
Lonsdale, Markus N. ;
Stroobants, Sigrid G. ;
Oyen, Wim J. G. ;
Kotzerke, Joerg ;
Hoekstra, Otto S. ;
Pruim, Jan ;
Marsden, Paul K. ;
Tatsch, Klaus ;
Hoekstra, Corneline J. ;
Visser, Eric P. ;
Arends, Bertjan ;
Verzijlbergen, Fred J. ;
Zijlstra, Josee M. ;
Comans, Emile F. I. ;
Lammertsma, Adriaan A. ;
Paans, Anne M. ;
Willemsen, Antoon T. ;
Beyer, Thomas ;
Bockisch, Andreas ;
Schaefer-Prokop, Cornelia ;
Delbeke, Dominique ;
Baum, Richard P. ;
Chiti, Arturo ;
Krause, Bernd J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (01) :181-200
[9]
Czernin J, 2007, J NUCL MED, V48, p78S
[10]
Doll J, 2004, NUKLEARMED-NUCL MED, V43, P72