Flow injection method for the determination of methotrexate with a column-packed oxidizing agent

被引:19
作者
Emara, S [1 ]
Razee, S [1 ]
ElShorbagi, AN [1 ]
Masujima, T [1 ]
机构
[1] HIROSHIMA UNIV,SCH MED,INST PHARMACEUT SCI,MINAMI KU,HIROSHIMA 734,JAPAN
关键词
flow injection; methotrexate; cerium(IV) trihydroxyhydroperoxide; spectrofluorimetric detection;
D O I
10.1039/an9962100183
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
A highly sensitive flow injection technique involving oxidative cleavage and spectrofluorimetric detection was developed for the determination of methotrexate. Cerium(rv) trihydroxyhydroperoxide (CTH) was introduced as a packed reactor for the construction of a derivatization column which is used in a flowing system for conversion of methotrexate into a highly fluorescent derivative. The oxidative cleavage of methotrexate occurs during the flow of carrier stream containing the drug through the CTH column. The optimum composition of the carrier stream was found to be 0.04 mol l(-1) phosphate buffer (pH 3.5). The flow rate was 0.5 ml min(-1) and the column temperature was 40 degrees C. The fluorescent product was monitored spectrofluorimetrically at excitation and emission wavelengths of 367 and 463 nm, respectively. The proposed method was successfully applied to the determination of methotrexate in pharmaceutical preparations.
引用
收藏
页码:183 / 188
页数:6
相关论文
共 15 条
[1]
COX AG, 1986, ANAL P, V23, P23
[2]
ASSAY FOR METHOTREXATE IN NANOMOLAR CONCENTRATIONS WITH SIMULTANEOUS DETECTION OF CITROVORUM FACTOR AND VINCRISTINE [J].
DEEN, WM ;
LEVY, PF ;
WEI, J ;
PARTRIDGE, RD .
ANALYTICAL BIOCHEMISTRY, 1981, 114 (02) :355-361
[3]
SIMULTANEOUS DETERMINATION OF NITRATE AND NITRITE BY FLOW-INJECTION ANALYSIS [J].
GINE, MF ;
BERGAMIN, H ;
ZAGATTO, EAG ;
REIS, BF .
ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) :191-197
[4]
SENSITIVITY ENHANCEMENTS FOR FLOW-INJECTION ANALYSIS INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY USING AN ONLINE PRECONCENTRATING ION-EXCHANGE COLUMN [J].
HARTENSTEIN, SD ;
RUZICKA, J ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1985, 57 (01) :21-25
[5]
OXIDATION OF AMINES WITH SULFONYL PEROXIDES [J].
HOFFMAN, RV .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1976, 98 (21) :6702-6704
[6]
HOFFMAN RV, 1983, CHEM PEROXIDES
[7]
FLUOROMETRIC-DETERMINATION OF METHOTREXATE IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING IN-LINE OXIDATION WITH HYDROGEN-PEROXIDE [J].
KUBO, H ;
UMIGUCHI, Y ;
FUKUMOTO, M ;
KINOSHITA, T .
ANALYTICAL SCIENCES, 1992, 8 (06) :789-792
[8]
VINYL POLYMER AGGLOMERATE BASED TRANSITION-METAL CATION CHELATING ION-EXCHANGE RESIN CONTAINING THE 8-HYDROXYQUINOLINE FUNCTIONAL-GROUP [J].
LANDING, WM ;
HARALDSSON, C ;
PAXEUS, N .
ANALYTICAL CHEMISTRY, 1986, 58 (14) :3031-3035
[9]
NELSON JA, 1977, CANCER RES, V37, P3970
[10]
AUTOMATED-DETERMINATION OF IRON IN SEAWATER BY CHELATING RESIN CONCENTRATION AND CHEMILUMINESCENCE DETECTION [J].
OBATA, H ;
KARATANI, H ;
NAKAYAMA, E .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1524-1528