FADC-based DAQ for HiRes fly's eye

被引:69
作者
Boyer, JH [1 ]
Knapp, BC [1 ]
Mannel, EJ [1 ]
Seman, M [1 ]
机构
[1] Columbia Univ, Dept Phys, Nevis Labs, Irvington, NY 10533 USA
关键词
The High Resolution Fly's Eye Experiment; HiRes; cosmic ray detector; air fluorescence technique; FADC; DAQ; parallel processing;
D O I
10.1016/S0168-9002(01)01517-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper describes a data acquisition system for optical telescopes studying extensive air showers for the High Resolution Fly's Eye Project at Dugway Proving Grounds, Utah. The measurements are based entirely on flash-analog-to-digital conversion of phototube signals, digitized continuously at 10 MHz, and stored in a deep (820 mus) pipeline. for deadtimeless readout following a parallel pipeline trigger. The massive parallel processing by digital signal processors and programmable logic devices is distributed site-wide, with 42 telescopes and a central facility linked by optical fiber. The system was designed and built at Columbia University, Nevis Laboratories. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:457 / 474
页数:18
相关论文
共 5 条
[1]  
ABUZAYAD T, 1997, P 25 ICRC, V7, P213
[2]   THE UTAH FLYS EYE DETECTOR [J].
BALTRUSAITIS, RM ;
CADY, R ;
CASSIDAY, GL ;
COOPER, R ;
ELBERT, JW ;
GERHARDY, PR ;
KO, S ;
LOH, EC ;
SALAMON, M ;
STECK, D ;
SOKOLSKY, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 240 (02) :410-428
[3]   A fiber-optic-based calibration system for the High Resolution Fly's Eye cosmic ray observatory [J].
Girard, JHV ;
Wiencke, LR ;
Archbold, GC ;
Bellido, JA ;
Belov, K ;
Boyer, JH ;
Everett, AA ;
Gray, RC ;
Jui, CCH ;
Knapp, BC ;
Mannel, EJ ;
Matthews, JN ;
Moore, SA ;
Mumford, JR ;
Roberts, MD ;
Shen, P ;
Sokolsky, PV ;
Springer, RW ;
Thomas, SB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 460 (2-3) :278-288
[4]  
JONES BF, 1999, P 26 ICRC, V5, P429
[5]   Radio-controlled xenon flashers for atmospheric monitoring at the HiRes cosmic ray observatory [J].
Wiencke, LR ;
Abu-Zayyad, T ;
Al-Seady, M ;
Belov, K ;
Bird, DJ ;
Boyer, J ;
Chen, GF ;
Clay, RW ;
Dai, HY ;
Dawson, BR ;
Denholm, P ;
Gloyn, J ;
He, D ;
Ho, Y ;
Huang, MA ;
Jui, CCH ;
Kidd, MJ ;
Kieda, DB ;
Knapp, B ;
Ko, S ;
Larson, K ;
Loh, EC ;
Mannel, EJ ;
Matthews, JN ;
Meyer, JR ;
Salman, A ;
Simpson, KM ;
Smith, JD ;
Sokolsky, P ;
Steenblik, D ;
Tang, JKK ;
Taylor, S ;
Thomas, SB ;
Wilkinson, CR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (2-3) :593-607