Prospects of real-time single-particle biological aerosol analysis: A comparison between laser-induced breakdown spectroscopy and aerosol time-of-flight mass spectrometry

被引:36
作者
Beddows, DCS [1 ]
Telle, HH [1 ]
机构
[1] Univ Coll Swansea, Dept Phys, Swansea SA2 8PP, W Glam, Wales
关键词
laser-induced breakdown spectroscopy; Raman spectroscopy; aerosol; biological; aerosol time-of-flight mass spectroscopy;
D O I
10.1016/j.sab.2005.05.018
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In this paper we discuss the prospects of real-time, in situ laser-induced breakdown spectroscopy applied for the identification and classification of bio-aerosols (including species of potential bio-hazard) within common urban aerosol mixtures. In particular, we address the issues associated with the picking out of bio-aerosols against common background aerosol particles, comparing laser-induced breakdown spectroscopy measurements with data from a mobile single-particle aerosol mass spectrometer (ATOFMS). The data from the latter provide statistical data over an extended period of time, highlighting the variation of the background composition. While single-particle bio-aerosols are detectable in principle, potential problems with small (similar to 1 mu m size) bio-aerosols have been identified; constituents of the air mass other than background aerosols, e.g. gaseous CO2 in conjunction with common background aerosols, may prevent unique recognition of the bio-particles. We discuss whether it is likely that laser-induced breakdown spectroscopy on its own can provide reliable, real-time identification of bio-aerosol in an urban environment, and it is suggested that more than one technique should be or would have to be used. A case for using a combination of laser-induced breakdown spectroscopy and Raman (and/or) laser-induced fluorescence spectroscopy is made. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1040 / 1059
页数:20
相关论文
共 52 条
[1]   Quantitative sampling using an Aerodyne aerosol mass spectrometer - 1. Techniques of data interpretation and error analysis [J].
Allan, JD ;
Jimenez, JL ;
Williams, PI ;
Alfarra, MR ;
Bower, KN ;
Jayne, JT ;
Coe, H ;
Worsnop, DR .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2003, 108 (D3)
[2]  
ALLEN JO, 01338 AR STAT U DEP
[3]  
ANGLELINA S, 2001, ENVIRON SCI TECHNOL, V35, P3130
[4]  
BEDDOWS DCS, 2000, THESIS U WALES SWANS
[5]   Neural network methodologies for mass spectra recognition [J].
Belic, I ;
Gyergyek, L .
VACUUM, 1997, 48 (7-9) :633-637
[6]  
BOTHEROYD IM, 1998, CLEO EUROPE EQEC 98
[7]   Single-pollen analysis by laser-induced breakdown spectroscopy and Raman microscopy [J].
Boyain-Goitia, AR ;
Beddows, DCS ;
Griffiths, BC ;
Telle, HH .
APPLIED OPTICS, 2003, 42 (30) :6119-6132
[8]   Implementation of laser-induced breakdown spectroscopy as a continuous emissions monitor for toxic metals [J].
Buckley, SG ;
Johnsen, HA ;
Hencken, KR ;
Hahn, DW .
WASTE MANAGEMENT, 2000, 20 (5-6) :455-462
[9]   Plasma volume considerations for analysis of gaseous and aerosol samples using laser-induced breakdown spectroscopy [J].
Carranza, JE ;
Hahn, DW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (11) :1534-1539
[10]   Assessment of the upper particle size limit for quantitative analysis of aerosols using laser-induced breakdown spectroscopy [J].
Carranza, JE ;
Hahn, DW .
ANALYTICAL CHEMISTRY, 2002, 74 (21) :5450-5454