Real-time rectilinear volumetric imaging

被引:33
作者
Yen, JT [1 ]
Smith, SW [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
关键词
D O I
10.1109/58.981389
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Current real-time volumetric scanners use a 2-D array to scan a pyramidal volume consisting of many sector scans stacked in the elevation direction. This scan format is primarily useful for cardiac imaging to avoid interference from the ribs. However, a real-time rectilinear volumetric scan with a wider field of view close to the transducer could prove more useful for abdominal, breast, or vascular imaging. In previous work, computer simulations of very sparse array transducer designs in a rectilinear volumetric scanner demonstrated that a Mills cross array showed the best overall performance given current system constraints. Consequently, a 94 x 94 Mills cross array including 372 active channels operating at 5 MHz has been developed on a flexible circuit interconnect. In addition, the beam former delay software and scan converter display software of the Duke volumetric scanner were modified to achieve real-time rectilinear volumetric scanning consisting of a 30-mm x 8-mm x 60-mm scan at a rate of 47 volumes/s. Real-time rectilinear volumetric images were obtained of tissue-mimicking phantoms, showing a spatial resolution of 1 to 2 mm. Images of carotid arteries in normal subjects demonstrated tissue penetration to 6 cm.
引用
收藏
页码:114 / 124
页数:11
相关论文
共 18 条
  • [1] ALAIS P, 1989, ACOUST IMAG, V18, P431
  • [2] Broad-bandwidth radiation patterns of sparse two-dimensional vernier arrays
    Brunke, SS
    Lockwood, GR
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (05) : 1101 - 1109
  • [3] 3-D ultrasound imaging: A review
    Fenster, A
    Downey, DB
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (06): : 41 - 51
  • [4] High-density flexible interconnect for two-dimensional ultrasound arrays
    Fiering, JO
    Hultman, P
    Lee, W
    Light, ED
    Smith, SW
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (03) : 764 - 770
  • [5] CALCULATION OF PRESSURE FIELDS FROM ARBITRARILY SHAPED, APODIZED, AND EXCITED ULTRASOUND TRANSDUCERS
    JENSEN, JA
    SVENDSEN, NB
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (02) : 262 - 267
  • [6] Light ED, 1998, ULTRASONIC IMAGING, V20, P1
  • [7] Light ED, 2000, ULTRASON, P1195, DOI 10.1109/ULTSYM.2000.921537
  • [8] Validation of real-time three-dimensional echocardiography for quantifying left ventricular volumes in the presence of a left ventricular aneurysm: In vitro and in vivo studies
    Qin, JX
    Jones, M
    Shiota, T
    Greenberg, NL
    Tsujino, H
    Firstenberg, MS
    Gupta, PC
    Zetts, AD
    Xu, Y
    Sun, JP
    Cardon, LA
    Odabashian, JA
    Flamm, SD
    White, RD
    Panza, JA
    Thomas, JD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) : 900 - 907
  • [9] Real-time three-dimensional echocardiography for measurement of left ventricular volumes
    Schmidt, MA
    Ohazama, CJ
    Agyeman, KO
    Freidlin, RZ
    Jones, M
    Laurienzo, JM
    Brenneman, CL
    Arai, AE
    von Ramm, OT
    Panza, JA
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (12) : 1434 - 1439
  • [10] Real-time three-dimensional echocardiography for determining right ventricular stroke volume in an animal model of chronic right ventricular volume overload
    Shiota, T
    Jones, M
    Chikada, M
    Fleishman, CE
    Castellucci, JB
    Cotter, B
    DeMaria, AN
    von Ramm, OT
    Kisslo, J
    Ryan, T
    Sahn, DJ
    [J]. CIRCULATION, 1998, 97 (19) : 1897 - 1900