Computing the centerline of a colon: A robust and efficient method based on 3D skeletons

被引:44
作者
Ge, YR
Stelts, DR
Wang, J
Vining, DJ
机构
[1] Wake Forest Univ, Dept Math & Comp Sci, Winston Salem, NC 27109 USA
[2] Wake Forest Univ, Dept Med Engn, Div Radiol Sci, Winston Salem, NC 27109 USA
[3] Wake Forest Univ, Sch Med, Dept Radiol, Winston Salem, NC 27109 USA
关键词
gastrointestinal tract; colon; endoscopy; virtual; computed tomography; techniques;
D O I
10.1097/00004728-199909000-00029
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present a robust and efficient algorithm for calculating the centerline of a computer-generated colon model created from helical CT image data. The centerline is an essential aid for navigating through complex anatomy such as the colon. Our algorithm involves three steps. In the first step, we generate a 3D skeleton of the binary colon volume using a fast topological thinning algorithm. In the second step, we employ a graph search algorithm to remove extra loops and branches. These loops and branches are caused by holes in the object that are artifacts produced during image segmentation. In the final step, we compute a smooth representation of the centerline by approximating the skeleton with cubic B-splines. This final step is necessary because the skeleton contains many abrupt changes in direction due to the discrete nature of image data. The user supplies two endpoints for the centerline; otherwise, the algorithm is fully automated. Experimental results demonstrate that the algorithm is not only robust but also efficient.
引用
收藏
页码:786 / 794
页数:9
相关论文
共 24 条
[1]  
Aho A. V., 1983, DATA STRUCTURES ALGO
[2]  
Ballard D.H., 1982, Computer Vision
[3]  
BARTELS R. H., 1987, INTRO SPLINES USE CO
[4]   BIOLOGICAL SHAPE AND VISUAL SCIENCE .1. [J].
BLUM, H .
JOURNAL OF THEORETICAL BIOLOGY, 1973, 38 (02) :205-287
[5]   DISTANCE TRANSFORMATIONS IN DIGITAL IMAGES [J].
BORGEFORS, G .
COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1986, 34 (03) :344-371
[6]  
Bullitt E, 1997, AM J NEURORADIOL, V18, P417
[7]   Computing the central path of colon lumen in Helical CT images [J].
Ge, Y ;
Stelts, DR ;
Zha, X ;
Wang, J ;
Vining, DJ .
MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 :702-713
[8]  
Geiger B., 1995, Computer Vision, Virtual Reality and Robotics in Medicine. First International Conference, CVRMed '95. Proceedings, P277, DOI 10.1007/BFb0034961
[9]   Colorectal polyp detection with CT colography: Two- versus three-dimensional techniques - Work in progress [J].
Hara, AK ;
Johnson, CD ;
Reed, JE ;
Ehman, RL ;
Ilstrup, DM .
RADIOLOGY, 1996, 200 (01) :49-54
[10]  
Haralick R. M., 1992, COMPUTER ROBOT VISIO