Motion correction of PET images using multiple acquisition frames

被引:195
作者
Picard, Y [1 ]
Thompson, CJ [1 ]
机构
[1] MCGILL UNIV,MONTREAL NEUROL INST,MONTREAL,PQ H3A 2B4,CANADA
基金
英国医学研究理事会;
关键词
acquisition; motion correction; positron emission tomography; video monitoring;
D O I
10.1109/42.563659
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Positron emission tomography (PET) is a relatively lengthy brain imaging method, Because it is difficult for the subject to stay still during the data acquisition, head motion during scans is a source of image degradation, A simple data acquisition technique to reduce the effect of this problem is described, The technique associates the incoming data with the real-space position of the head, During the PET scan, the head position is constantly monitored with two video cameras and compared to its initial position, Every time the displacement for a region within the field of view (FOV) is larger than a specified threshold displacement, the PET data acquisition system starts to save the PET data in a new frame, The total number of frames required for a complete study depends on the magnitude of the head motion during the study and on the threshold displacement, At the end of the study, all the acquired frames are reconstructed independently and each image is rotated and translated to coincide with the initial position, When these images are summed, they produce a final image with fewer motion artefacts.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 13 条
[1]  
[Anonymous], 1986, NUMERICAL RECIPES C
[2]  
DAUBE-WITHERSPOON M E, 1990, Journal of Nuclear Medicine, V31, P816
[3]   PERFORMANCE EVALUATION OF THE PC-2048 - A NEW 15-SLICE ENCODED-CRYSTAL PET SCANNER FOR NEUROLOGICAL STUDIES [J].
EVANS, AC ;
THOMPSON, CJ ;
MARRETT, S ;
MEYER, E ;
MAZZA, M .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (01) :90-98
[4]  
GOLDSTEIN H, 1980, CLASSICAL MECHANICS
[5]  
GOLDSTEIN SR, 1994, J NUCL MED, V35, pP40
[6]  
GREEN MV, 1994, J NUCL MED, V35, P1538
[7]   3-D PHANTOM TO SIMULATE CEREBRAL BLOOD-FLOW AND METABOLIC IMAGES FOR PET [J].
HOFFMAN, EJ ;
CUTLER, PD ;
DIGBY, WM ;
MAZZIOTTA, JC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :616-620
[8]   Compensation methods for head motion detected during PET imaging [J].
Menke, M ;
Atkins, MS ;
Buckley, KR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (01) :310-317
[9]  
MINTUN M A, 1990, Journal of Nuclear Medicine, V31, P816
[10]   DIGITIZED VIDEO SUBJECT POSITIONING AND SURVEILLANCE SYSTEM FOR PET [J].
PICARD, Y ;
THOMPSON, CJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1024-1029