Performance investigation of flat plate, v-corrugated and finned air collectors

被引:178
作者
Karim, MA [1 ]
Hawlader, MNA
机构
[1] Univ Melbourne, Dept Mech & Mfg Engn, Fac Engn, Victoria, Vic 3010, Australia
[2] Natl Univ Singapore, Dept Mech & Mfg Engn, Singapore 119260, Singapore
关键词
D O I
10.1016/j.energy.2005.03.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, flat plate, finned and v-corrugated air heaters were investigated both experimentally and theoretically in an effort to improve the performance of conventional air heaters. Collectors were also tested in double pass mode to investigate the extent of improvement in efficiency that could be achieved without increasing the collector size or cost. A series of experiments were conducted, based on the ASHRAE standard, under climatic conditions of Singapore. The performance of all three collectors was examined over a wide range of operating and design conditions. The v-corrugated collector was found to be the most efficient collector and the flat plate collector to be the least efficient. Results showed that the v-corrugated collector is 10-15 and 5-11% more efficient in single pass and double pass modes, respectively, compared to flat plate collectors. The double pass operation of the collector improved the efficiency of all three collectors. The improvement in efficiency for double pass mode was most significant in the flat plate collector and least in the v-groove collectors. (C) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:452 / 470
页数:19
相关论文
共 24 条
[1]  
Abu-Qudais M. K., 1996, International Journal of Solar Energy, V18, P137, DOI 10.1080/01425919608914312
[2]   TRANSIENT-BEHAVIOR OF A MATRIX SOLAR AIR HEATER [J].
ALNIMR, MA .
ENERGY CONVERSION AND MANAGEMENT, 1993, 34 (08) :649-656
[3]  
[Anonymous], 1977, 9377 ASHRAE
[4]   A SOLAR AIR HEATER FOR LOW-TEMPERATURE APPLICATIONS [J].
CHOUDHURY, C ;
ANDERSEN, SL ;
REKSTAD, J .
SOLAR ENERGY, 1988, 40 (04) :335-343
[5]  
*CO STAT U, 1974, NSFRANNSEGI37815PR74
[6]  
Duffie JA., 1980, Solar engineering of thermal processes
[7]   TRANSIENT ANALYSIS OF SOLAR AIR HEATERS USING A FINITE-DIFFERENCE TECHNIQUE [J].
GARG, HP ;
CHANDRA, R ;
RANI, U .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1981, 5 (03) :243-252
[8]   THERMAL PERFORMANCE ENHANCEMENT OF SOLAR AIR HEATERS, BY A FAN-BLOWN ABSORBER PLATE WITH RECTANGULAR FINS [J].
HACHEMI, A .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1995, 19 (07) :567-577
[9]  
Hawlader M. N. A., 1990, International Journal of Solar Energy, V8, P1, DOI 10.1080/01425919008909705
[10]  
Heaton H.S., 1964, INT J HEAT MASS TRAN, V7, P763, DOI [DOI 10.1016/0017-9310(64)90006-7, 10.1016/0017-9310(64)90006-7]