Electrochemical sensor arrays

被引:47
作者
Stefan, RI [1 ]
van Staden, JF
Aboul-Enein, HY
机构
[1] Univ Pretoria, Dept Chem, ZA-0002 Pretoria, South Africa
[2] Dept Biol & Med Res MBC03, Bioanalyt & Drug Dev Lab, POB 3354, Riyadh 11211, Saudi Arabia
关键词
sensor arrays; design; chemometrics;
D O I
10.1080/10408349891199293
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The importance of sensor arrays in environmental, food and clinical analysis is discussed. The possible designs of sensor arrays is shown. The most reliable mathematical models for data processing are presented. The importance of different types of electrochemical sensor arrays in analytical chemistry as well as their performances are shown.
引用
收藏
页码:133 / 153
页数:21
相关论文
共 139 条
[1]   DISCRIMINATION OF LIQUOR AROMAS BY PATTERN-RECOGNITION ANALYSIS OF RESPONSES FROM A GAS SENSOR ARRAY [J].
AISHIMA, T .
ANALYTICA CHIMICA ACTA, 1991, 243 (02) :293-300
[2]   VERSATILE MICROCONTROLLED GAS SENSOR ARRAY SYSTEM USING THE QUARTZ MICROBALANCE PRINCIPLE AND PATTERN-RECOGNITION METHODS [J].
AUGE, J ;
HAUPTMANN, P ;
HARTMANN, J ;
ROSLER, S ;
LUCKLUM, R .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 26 (1-3) :181-186
[3]   Application of principal component analysis for the characterisation of a piezoelectric sensors array [J].
Barkó, G ;
Hlavay, J .
ANALYTICA CHIMICA ACTA, 1998, 367 (1-3) :135-143
[4]   APPLICATION OF PATTERN-RECOGNITION AND PIEZOELECTRIC SENSOR ARRAY FOR THE DETECTION OF ORGANIC-COMPOUNDS [J].
BARKO, G ;
PAPP, B ;
HLAVAY, J .
TALANTA, 1995, 42 (03) :475-482
[5]   SMART CHEMICAL SENSING ARRAYS USING TIN OXIDE SENSORS AND ANALOG WINNER-TAKE-ALL SIGNAL-PROCESSING [J].
BEDNARCZYK, D ;
DEWEERTH, SP .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 27 (1-3) :271-274
[6]   Gel-integrated microelectrode arrays for direct voltammetric measurements of heavy metals in natural waters and other complex media [J].
Belmont-Hébert, C ;
Tercier, ML ;
Buffle, J ;
Fiaccabrino, GC ;
de Rooij, NF ;
Koudelka-Hep, M .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2949-2956
[7]   AN EVALUATION OF ULTRATHIN RING AND BAND MICROELECTRODES AS AMPEROMETRIC SENSORS IN ELECTROCHEMICAL FLOW CELLS [J].
BIXLER, JW ;
FIFIELD, M ;
POLER, JC ;
BOND, AM ;
THORMANN, W .
ELECTROANALYSIS, 1989, 1 (01) :23-33
[8]   The application of metalloporphyrins as coating material for quartz microbalance-based chemical sensors [J].
Brunink, JAJ ;
DiNatale, C ;
Bungaro, F ;
Davide, FAM ;
DAmico, A ;
Paolesse, R ;
Boschi, T ;
Faccio, M ;
Ferri, G .
ANALYTICA CHIMICA ACTA, 1996, 325 (1-2) :53-64
[9]   Experience of the National Institute of Metrology (INM) in development and certification of reference materials used in the metrological assurance of clinical laboratory measurements [J].
Buzoianu, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (3-4) :479-485
[10]  
CAMMANN K, 1994, ANALUSIS, V22, pM19