Development and validation of a high throughput and robust LC-MS/MS with electrospray ionization method for simultaneous quantitation of diltiazem and its two metabolites in human plasma: Application to a bioequivalence study

被引:22
作者
Dasandi, Bhavesh [1 ,2 ]
Shah, Sanjay [2 ]
Shivprakash [1 ]
机构
[1] Synchron Res Serv Private Ltd, Ahmadabad 380054, Gujarat, India
[2] Pilvai Sci Coll, Dept Chem, Vijapur, Gujarat, India
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2009年 / 877卷 / 8-9期
关键词
Diltiazem; O-desacetylediltiazem; N-desmethylediltiazem; LC-MS/MS; Human plasma; Acquity; UPLC; PERFORMANCE LIQUID-CHROMATOGRAPHY; MAIN METABOLITES; SOLID-PHASE; PHARMACOKINETICS; ASSAY; EXTRACTION;
D O I
10.1016/j.jchromb.2009.02.016
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
A high throughput and specific method using ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of diltiazem and its two metabolite (N-desmethyldiltiazem and C-desacetyldiltiazem) in human plasma. A one-step liquid-liquid extraction (LLE) with methyl-t-butyl ether(MTBE) involved for the extraction of diltiazem (DLTZ), metabolites (DMeD and DAcD) and internal standard. Analytes were chromatographed on a ACQUITY UPLC (TM) BEH C-18 column (100 mm x 2.1 mm. i.d., 1.7 mu m) with isocratic elution at a flow rate of 0.2 ml/min using 10 mM ammonium acetate buffer-acetonitrile (25:75, v/v). The Quattro Premier XE LC-MS/MS was operated under the multiple reaction-monitoring mode (MRM) using the electrospray ionization technique. Using 300 mu L plasma, the method was validated over the concentration range 0.48-639.9 ng/mL for DLTZ and 0.24-320.1 for DMeD and 0.24-320.7 ng/ml for DAcD, with a lower limit of quantification of 0.48 ng/mL for DLTZ and 0.24 ng/ml. for metabolites. The intra- and inter-clay precision and accuracy were within 10.0%. The recovery was 77.4%, 76.0%, 74.5% and 74.1% for DLTZ, DMeD, DAcD and Ziprasidone, respectively. Total run time was 2.0 min only. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:791 / 798
页数:8
相关论文
共 16 条
[1]
DETERMINATION OF SERUM DILTIAZEM CONCENTRATIONS IN A PHARMACOKINETIC STUDY USING GAS-CHROMATOGRAPHY WITH ELECTRON-CAPTURE DETECTION [J].
ALEBICKOLBAH, T ;
PLAVSIC, F .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (8-12) :915-918
[2]
DETERMINATION OF DILTIAZEM AND ITS MAIN METABOLITES IN HUMAN PLASMA BY AUTOMATED SOLID-PHASE EXTRACTION AND HIGHPERFORMANCE LIQUID-CHROMATOGRAPHY - A NEW METHOD OVERCOMING INSTABILITY OF THE COMPOUNDS AND INTERFERENCE PROBLEMS [J].
ASCALONE, V ;
LOCATELLI, M ;
MALAVASI, B .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 657 (01) :133-140
[3]
PRINCIPLES OF DRUG BIODISPOSITION IN THE NEONATE - A CRITICAL-EVALUATION OF THE PHARMACOKINETIC-PHARMACODYNAMIC INTERFACE .2. [J].
BESUNDER, JB ;
REED, MD ;
BLUMER, JL .
CLINICAL PHARMACOKINETICS, 1988, 14 (05) :261-286
[4]
SIMULTANEOUS DETERMINATION OF DILTIAZEM AND QUINIDINE IN HUMAN PLASMA BY LIQUID-CHROMATOGRAPHY [J].
CARIGNAN, G ;
CARRIER, K ;
LAGANIERE, S ;
LESSARD, M .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 672 (02) :261-269
[5]
Simultaneous enantioseparation of cis-diltiazem hydrochloride and its metabolite cis-desacetyldiltiazem using high-performance liquid chromatography and capillary electrophoresis [J].
Chankvetadze, B ;
Kartozia, I ;
Blaschke, G .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 27 (1-2) :161-166
[6]
A simple and sensitive high-performance liquid chromatography assay of diltiazem and main metabolites in renal transplanted patients [J].
Christensen, H ;
Carlson, E ;
Åsberg, A ;
Schram, L ;
Berg, KJ .
CLINICA CHIMICA ACTA, 1999, 283 (1-2) :63-75
[7]
Matrix effect in bio-analysis of illicit drugs with LC-MS/MS: Influence of ionization type, sample preparation, and biofluid [J].
Dams, R ;
Huestis, MA ;
Lambert, WE ;
Murphy, CM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (11) :1290-1294
[8]
Nonlinear calibrations on the assay of dilitiazem and two of its metabolites from plasma samples by means of liquid chromatography and ESI/MS2 detection:: application to a bioequivalence study [J].
Georgita, Cristina ;
Albu, Florin ;
David, Victor ;
Medvedovici, Andrei .
BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (03) :289-297
[9]
HOGLUND P, 1989, THER DRUG MONIT, V11, P558
[10]
HPLC determination of diltiazem in human plasma and its application to pharmacokinetics in humans [J].
Li, K ;
Zhang, X ;
Zhao, FL .
BIOMEDICAL CHROMATOGRAPHY, 2003, 17 (08) :522-525