Conformal therapy for pancreatic cancer:: Variation of organ position due to gastrointestinal distention -: Implications for treatment planning

被引:30
作者
Horst, E [1 ]
Micke, O [1 ]
Moustakis, C [1 ]
Schuck, A [1 ]
Schäfer, U [1 ]
Willich, NA [1 ]
机构
[1] Univ Munster, Dept Radiat Oncol, D-48129 Munster, Germany
关键词
pancreas; therapeutic radiology; treatment planning;
D O I
10.1148/radiol.2223010639
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To quantify nonrespiratory organ motion in the pancreatic region and its effect on clinical target volume. MATERIALS AND METHODS: Three-dimensional translations of the geometric centers of the volumes of interest-pancreatic head, body, and tail; left and right kidney; and the superior mesenteric artery-were measured in 20 patients by analyzing three spiral computed tomographic (CT) protocols performed at static exhalation and representing differential gastrointestinal distention. Wilcoxon test for paired differences was applied to determine statistical significance (P < .05). Spearman rank correlation coefficients were calculated between combinations of statistically significant translations. With the assumption that the organ positions were represented by a three-dimensional Gaussian distribution that occurs during treatment, clinical target volume expansions were calculated to account for organ motion and a typical setup error. RESULTS: Significant translations of the volume of interest were observed. The most mobile parts of the target organs were the pancreatic tail (P = .001) and the superior mesenteric artery (P = .01). Larger variations from the mean in the planning CT protocol in which negative contrast material was used usually resulted in a slightly larger clinical target volume expansion. CONCLUSION: Our data may provide a basis for further studies of organ motion and ways of modifying treatment margins. (C) RSNA, 2002.
引用
收藏
页码:681 / 686
页数:6
相关论文
共 21 条
[1]   Respiration-induced motion of the kidneys in whole abdominal radiotherapy: Implications for treatment planning and late toxicity [J].
Ahmad, NR ;
Huq, MS ;
Corn, BW .
RADIOTHERAPY AND ONCOLOGY, 1997, 42 (01) :87-90
[2]   Target volume definition for upper abdominal irradiation using CT scans obtained during inhale and exhale phases [J].
Aruga, T ;
Itami, J ;
Aruga, M ;
Nakajima, K ;
Shibata, K ;
Nojo, T ;
Yasuda, S ;
Uno, T ;
Hara, R ;
Isobe, K ;
Machida, N ;
Ito, H .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02) :465-469
[3]   Three dimensional planning target volumes: A model and a software tool [J].
AustinSeymour, M ;
Kalet, I ;
McDonald, J ;
KromhoutSchiro, S ;
Jacky, J ;
Hummel, S ;
Unger, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1073-1080
[4]   Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging [J].
Balter, JM ;
Lam, KL ;
McGinn, CJ ;
Lawrence, TS ;
Ten Haken, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (04) :939-943
[5]  
Chu JCH, 1993, MED DOSIM, V17, P199
[6]   THIN-SECTION CONTRAST-ENHANCED COMPUTED-TOMOGRAPHY ACCURATELY PREDICTS THE RESECTABILITY OF MALIGNANT PANCREATIC NEOPLASMS [J].
FUHRMAN, GM ;
CHARNSANGAVEJ, C ;
ABBRUZZESE, JL ;
CLEARY, KR ;
MARTIN, RG ;
FENOGLIO, CJ ;
EVANS, DB .
AMERICAN JOURNAL OF SURGERY, 1994, 167 (01) :104-113
[7]  
Gunderson, 1997, PRINCIPLES PRACTICE
[8]   3-DIMENSIONAL CONFORMAL PANCREAS TREATMENT - COMPARISON OF 4-FIELD TO 6-FIELD TECHNIQUES [J].
HIGGINS, PD ;
SOHN, JW ;
FINE, RM ;
SCHELL, MC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (03) :605-609
[9]   ACCURATE FRAMELESS REGISTRATION OF MR AND CT IMAGES OF THE HEAD - APPLICATIONS IN PLANNING SURGERY AND RADIATION-THERAPY [J].
HILL, DLG ;
HAWKES, DJ ;
GLEESON, MJ ;
COX, TCS ;
STRONG, AJ ;
WONG, WL ;
RUFF, CF ;
KITCHEN, ND ;
THOMAS, DGT ;
SOFAT, A ;
CROSSMAN, JE ;
STUDHOLME, C ;
GANDHE, AJ ;
GREEN, SEM ;
ROBINSON, GP .
RADIOLOGY, 1994, 191 (02) :447-454
[10]   Normal enhancement of the small bowel: Evaluation with spiral CT [J].
Horton, KM ;
Eng, J ;
Fishman, EK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (01) :67-71