Configuration space analysis of common cost functions in radiotherapy beam-weight optimization algorithms

被引:18
作者
Rowbottom, CG
Webb, S
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Trust, Sutton SM2 5PT, Surrey, England
关键词
D O I
10.1088/0031-9155/47/1/305
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The successful implementation of downhill search engines in radiotherapy optimization algorithms depends on the absence of local minima in the search space. Such techniques are much faster than stochastic optimization methods but may become trapped in local minima if they exist. A technique known as 'configuration space analysis' was applied to examine the search space of cost functions used in radiotherapy beam-weight optimization algorithms. A downhill-simplex beam-weight optimization algorithm was run repeatedly to produce a frequency distribution of final cost values. By plotting the frequency distribution as a function of final cost, the existence of local minima can be determined. Common cost functions such as the quadratic deviation of dose to the planning target volume (PTV), integral dose to organs-at-risk (OARs), dose-threshold and dose-volume constraints for OARs were studied. Combinations of the cost functions were also considered. The simple cost function terms such as the quadratic PTV dose and integral dose to OAR cost function terms are not susceptible to local minima. In contrast. (lose-threshold and dose-volume OAR constraint cost function terms are able to produce local minima in the example case studied.
引用
收藏
页码:65 / 77
页数:13
相关论文
共 23 条
[1]  
Bortfeld T, 1997, PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, P1
[2]   Optimized planning using physical objectives and constraints [J].
Bortfeld, T .
SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (01) :20-+
[3]   METHODS OF IMAGE-RECONSTRUCTION FROM PROJECTIONS APPLIED TO CONFORMATION RADIOTHERAPY [J].
BORTFELD, T ;
BURKELBACH, J ;
BOESECKE, R ;
SCHLEGEL, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) :1423-1434
[4]  
Carol MP, 1997, PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, P317
[5]   Multiple local minima in radiotherapy optimization problems with dose-volume constraints [J].
Deasy, JO .
MEDICAL PHYSICS, 1997, 24 (07) :1157-1161
[6]   APPLICATION OF FAST SIMULATED ANNEALING TO OPTIMIZATION OF CONFORMAL RADIATION TREATMENTS [J].
MAGERAS, GS ;
MOHAN, R .
MEDICAL PHYSICS, 1993, 20 (03) :639-647
[7]  
MOHAN R, 1992, MED PHYS, V19, P934
[8]   VERY FAST SIMULATED REANNEALING IN RADIATION-THERAPY TREATMENT PLAN OPTIMIZATION [J].
MORRILL, SM ;
LAM, KS ;
LANE, RG ;
LANGER, M ;
ROSEN, II .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :179-188
[9]   CONSTRAINED SIMULATED ANNEALING FOR OPTIMIZED RADIATION-THERAPY TREATMENT PLANNING [J].
MORRILL, SM ;
LANE, RG ;
ROSEN, II .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1990, 33 (03) :135-144
[10]   A SIMPLEX-METHOD FOR FUNCTION MINIMIZATION [J].
NELDER, JA ;
MEAD, R .
COMPUTER JOURNAL, 1965, 7 (04) :308-313