Progress in high field MRI at the University of Florida

被引:24
作者
Beck, B
Plant, DH
Grant, SC
Thelwall, PE
Silver, X
Mareci, TH
Benveniste, H
Smith, M
Collins, C
Crozier, S
Blackband, SJ [1 ]
机构
[1] Univ Florida, McKnight Brain Inst, Gainesville, FL 32607 USA
[2] Univ Florida, Dept Neurosci, Gainesville, FL 32607 USA
[3] Univ Florida, Dept Biochem & Mol Biol, Gainesville, FL 32607 USA
[4] Univ Florida, Ctr Struct Biol, Gainesville, FL 32607 USA
[5] Natl High Magnet Field Lab, Tallahassee, FL 32310 USA
[6] Brookhaven Natl Lab, SUNY SB Med Dept, Dept Anesthesiol, New York, NY USA
[7] Penn State Coll Med, Dept Radiol, Hershey, PA USA
[8] Univ Queensland, Ctr Magnet Resonance, St Lucia, Qld 4067, Australia
来源
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE | 2002年 / 13卷 / 03期
关键词
high field MRI; University of Florida; signal-to-noise ratio;
D O I
10.1016/S1352-8661(01)00140-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this article we report on progress in high magnetic field MRI at the University of Florida in support of our new 750MHz wide bore and 11.7T/40cm MR instruments. The primary emphasis is on the associated rf technology required, particularly high frequency volume and phased array coils. Preliminary imaging results at 750MHz are presented. Our results imply that the pursuit of even higher fields seems warranted. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:152 / 157
页数:6
相关论文
共 13 条
[1]   Phased array imaging on a 4.7T/33cm animal research system [J].
Beck, BL ;
Blackband, SJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (11) :4292-4294
[2]   MR microscopy of perfused brain slices [J].
Blackband, SJ ;
Bui, JD ;
Buckley, DL ;
Zelles, T ;
Plant, HD ;
Inglis, BA ;
Phillips, MI .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) :1012-1015
[3]  
Buckley DL, 1999, MAGNET RESON MED, V41, P137, DOI 10.1002/(SICI)1522-2594(199901)41:1<137::AID-MRM19>3.0.CO
[4]  
2-Y
[5]  
Grant SC, 2000, MAGNET RESON MED, V44, P19, DOI 10.1002/1522-2594(200007)44:1<19::AID-MRM4>3.0.CO
[6]  
2-F
[7]   MR microscopy of multicomponent diffusion in single neurons [J].
Grant, SC ;
Buckley, DL ;
Gibb, S ;
Webb, AG ;
Blackband, SJ .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) :1107-1112
[8]   AN EFFICIENT, HIGHLY HOMOGENEOUS RADIOFREQUENCY COIL FOR WHOLE-BODY NMR IMAGING AT 1.5-T [J].
HAYES, CE ;
EDELSTEIN, WA ;
SCHENCK, JF ;
MUELLER, OM ;
EASH, M .
JOURNAL OF MAGNETIC RESONANCE, 1985, 63 (03) :622-628
[9]   Visualization of neural tissue water compartments using biexponential diffusion tensor MRI [J].
Inglis, BA ;
Bossart, EL ;
Buckley, DL ;
Wirth, ED ;
Mareci, TH .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :580-587
[10]   THE NMR PHASED-ARRAY [J].
ROEMER, PB ;
EDELSTEIN, WA ;
HAYES, CE ;
SOUZA, SP ;
MUELLER, OM .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :192-225