The inadequacy of standard radiographs in detecting flaws in the cement mantle

被引:19
作者
Reading, AD [1 ]
McCaskie, AW [1 ]
Gregg, PJ [1 ]
机构
[1] Newcastle Univ, Sch Surg Serv, Dept Trauma & Orthopaed Surg, Sch Med, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1999年 / 81B卷 / 01期
关键词
D O I
10.1302/0301-620X.81B1.0810167
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Radiological assessment of the cement mantle is used routinely to determine the outcome of total hip replacement. We performed a simulated replacement arthroplasty on cadaver femora and took standard postoperative radiographs. The femora were then sectioned into 7 mm slices starting at the calcar, and high-resolution faxitron radiographs were taken of these sections. Analysis of the faxitron images showed that defects in the cement mantle were observed up to 100 times more frequently than on the standard films. We therefore encourage the search for a better technique in assessing the cement mantle.
引用
收藏
页码:167 / 170
页数:4
相关论文
共 12 条
[1]
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[2]
The influence of cementing technique and blood on the strength of the bone-cement interface [J].
Bannister, G.C. ;
Miles, A.W. .
Engineering in Medicine, 1988, 17 (03) :131-133
[3]
IMPROVED CEMENTING TECHNIQUES AND FEMORAL COMPONENT LOOSENING IN YOUNG-PATIENTS WITH HIP-ARTHROPLASTY - A 12-YEAR RADIOGRAPHIC REVIEW [J].
BARRACK, RL ;
MULROY, RD ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :385-389
[4]
CENTRIFUGATION AS A METHOD OF IMPROVING TENSILE AND FATIGUE PROPERTIES OF ACRYLIC BONE-CEMENT [J].
BURKE, DW ;
GATES, EI ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (08) :1265-1273
[5]
FRACTURE AND LOOSENING OF CHARNLEY FEMORAL STEMS - COMPARISON BETWEEN 1ST-GENERATION AND SUBSEQUENT DESIGNS [J].
DALL, DM ;
LEARMONTH, ID ;
SOLOMON, MI ;
MILES, AW ;
DAVENPORT, JM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :259-265
[7]
A FRACTOGRAPHIC INVESTIGATION OF PMMA BONE-CEMENT FOCUSING ON THE RELATIONSHIP BETWEEN POROSITY REDUCTION AND INCREASED FATIGUE LIFE [J].
JAMES, SP ;
JASTY, M ;
DAVIES, J ;
PIEHLER, H ;
HARRIS, WH .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (05) :651-662
[8]
CLINICAL AND RADIOGRAPHIC EVALUATION OF TOTAL HIP-REPLACEMENT - A STANDARD SYSTEM OF TERMINOLOGY FOR REPORTING RESULTS [J].
JOHNSTON, RC ;
FITZGERALD, RH ;
HARRIS, WH ;
POSS, R ;
MULLER, ME ;
SLEDGE, CB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (02) :161-168
[9]
LINDEN U, 1989, CLIN ORTHOP RELAT R, V247, P148
[10]
Radiological evaluation of the interfaces after cemented total hip replacement - Interobserver and intraobserver agreement [J].
McCaskie, AW ;
Brown, AR ;
Thompson, JR ;
Gregg, PJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (02) :191-194