Body composition by DEXA in older adults: Accuracy and influence of scan mode

被引:42
作者
Clasey, JL
Hartman, ML
Kanaley, J
Wideman, L
Teates, CD
Bouchard, C
Weltman, A
机构
[1] UNIV VIRGINIA, EXERCISE PHYSIOL LAB, DEPT INTERNAL MED, CHARLOTTESVILLE, VA 22908 USA
[2] UNIV VIRGINIA, DEPT HUMAN SERV, CHARLOTTESVILLE, VA 22908 USA
[3] UNIV VIRGINIA, DEPT RADIOL, CHARLOTTESVILLE, VA 22908 USA
[4] UNIV LAVAL, PHYS ACT SCI LAB, Ste Foy, PQ G1K 7P4, CANADA
关键词
dexa; bone mineral content; bone mineral density; fat-free mass; percent body fat; X-RAY ABSORPTIOMETRY; DXA PENCIL-BEAM; FAN-BEAM; HUMANS;
D O I
10.1097/00005768-199704000-00020
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Dual energy x-ray absorptiometry (DEXA) measures bone mineral content (BMC), bone mineral density (BMD), fat-free mass (FFM), and provides estimates of percent body fat. Changes in scan mode geometry (pencil beam vs array) may impact these measures and body composition estimates using multi-compartment models. Forty-one adults, ages 59-79 yr, were scanned in each mode and also underwent hydrostatic weighing and measurement of total body water (tritiated water dilution). The effect of scan mode on measurement of DEXA BMC, BMD, FFM, and percent body fat (DEXA %Fat) was examined. The effect of scan mode on percentage body fat determined by a 4-compartment body composition model (4 Comp %Fat)) and comparison of DEXA %Fat and 4 Comp %Fat were also examined. BMC and DEXA %Fat were greater (1.3% and 3.9%, respectively, P < 0.01), and BMD and FFM were lower (1.1% and 1.9%, respectively, P < 0.01) with array scan mode. The 4 Comp %Fat was significantly greater (0.2%) when the array scan mode measurements of total body bone mineral were used; however, these differences were physiologically inconsequential. Comparison between DEXA %Fat and 4 Comp %Fat measures revealed a total error of +/- 5.0% in the older adults examined. These results indicate significant scan mode differences in total body BMC, BMD, FFM, and DEXA %Fat measurements and demonstrate the importance of using a single DEXA scan mode for clinical investigation, particularly with longitudinal studies. For all investigations with DEXA, the scan mode should be reported. Furthermore, the error associated with using DEXA alone to estimate percent fat in an older population suggests that this technique is unacceptable in a research setting.
引用
收藏
页码:560 / 567
页数:8
相关论文
共 16 条
  • [1] BODY-COMPOSITION IN ELDERLY PEOPLE - EFFECT OF CRITERION ESTIMATES ON PREDICTIVE EQUATIONS
    BAUMGARTNER, RN
    HEYMSFIELD, SB
    LICHTMAN, S
    WANG, J
    PIERSON, RN
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1991, 53 (06) : 1345 - 1353
  • [2] DUAL X-RAY ABSORPTIOMETRY - A COMPARISON BETWEEN FAN-BEAM AND PENCIL BEAM SCANS
    BLAKE, GM
    PARKER, JC
    BUXTON, FMA
    FOGELMAN, I
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (790) : 902 - 906
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] SWITCHING FROM DXA PENCIL-BEAM TO FAN-BEAM .2. STUDIES IN-VIVO
    EIKEN, P
    KOLTHOFF, N
    BARENHOLDT, O
    HERMANSEN, F
    NIELSEN, SP
    [J]. BONE, 1994, 15 (06) : 671 - 676
  • [5] SWITCHING FROM DXA PENCIL-BEAM TO FAN-BEAM .1. STUDIES IN-VITRO AT 4 CENTERS
    EIKEN, P
    BARENHOLDT, O
    JENSEN, LB
    GRAM, J
    NIELSEN, SP
    [J]. BONE, 1994, 15 (06) : 667 - 670
  • [6] CROSS-CALIBRATION OF DXA EQUIPMENT - UPGRADING FROM A HOLOGIC QDR 1000/W TO A QDR-2000
    FAULKNER, KG
    GLUER, CC
    ESTILO, M
    GENANT, HK
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1993, 52 (02) : 79 - 84
  • [7] HOW VALID ARE ISOTOPIC MEASUREMENTS OF FATTY-ACID OXIDATION
    HEILING, VJ
    MILES, JM
    JENSEN, MD
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1991, 261 (05): : E572 - E577
  • [8] HEYMSFIELD SB, 1991, NUTR REV, V49, P97, DOI 10.1111/j.1753-4887.1991.tb02997.x
  • [9] BODY-COMPOSITION OF HUMANS - COMPARISON OF 2 IMPROVED 4-COMPARTMENT MODELS THAT DIFFER IN EXPENSE, TECHNICAL COMPLEXITY, AND RADIATION EXPOSURE
    HEYMSFIELD, SB
    LICHTMAN, S
    BAUMGARTNER, RN
    WANG, J
    KAMEN, Y
    ALIPRANTIS, A
    PIERSON, RN
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1990, 52 (01) : 52 - 58
  • [10] *HOL INC, 1992, 0800384 HOL INC