Economic, energy and GHG emissions performance evaluation of a WhisperGen Mk IV Stirling engine μ-CHP unit in a domestic dwelling

被引:38
作者
Conroy, G. [1 ]
Duffy, A. [1 ,2 ]
Ayompe, L. M. [1 ,2 ]
机构
[1] Dublin Inst Technol, Sch Civil & Bldg Serv Engn, Dublin 1, Ireland
[2] Dublin Inst Technol, Dublin Energy Lab, Dublin 1, Ireland
关键词
mu-CHP; Stirling engine; Condensing gas boiler; WhisperGen; Microgeneration; MICRO-COGENERATION SYSTEMS; POWER;
D O I
10.1016/j.enconman.2014.02.002
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents an assessment of the energy, economic and greenhouse gas emissions performances of a WhisperGen Mk IV Stirling engine mu-CHP unit for use in a conventional house in the Republic of Ireland. The energy performance data used in this study was obtained from a field trial carried out in Belfast, Northern Ireland during the period June 2004-July 2005 by Northern Ireland Electricity and Phoenix Gas working in collaboration with Whispertech UK. A comparative performance analysis between the mu-CHP unit and a condensing gas boiler revealed that the mu-CHP unit resulted in an annual cost saving of (sic)180 with an incremental simple payback period of 13.8 years when compared to a condensing gas boiler. Electricity imported from the grid decreased by 20.8% while CO2 emissions decreased by 16.1%. The mu-CHP unit used 2889 kWh of gas more than the condensing gas boiler. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:465 / 474
页数:10
相关论文
共 26 条
[1]   Techno-economic assessment and optimization of Stirling engine micro-cogeneration systems in residential buildings [J].
Alanne, Kari ;
Soderholm, Niklas ;
Siren, Kai ;
Beausoleil-Morrison, Ian .
ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (12) :2635-2646
[2]  
[Anonymous], 2010, Projected Costs of Generating Electricity
[3]  
[Anonymous], ESSENTIALS ENG EC AN
[4]   Residential application of internal combustion engine based cogeneration in cold climate-Canada [J].
Aussant, Christianne D. ;
Fung, Alan S. ;
Ugursal, V. Ismet ;
Taherian, Hessam .
ENERGY AND BUILDINGS, 2009, 41 (12) :1288-1298
[5]   Analysis of innovative micro-CHP systems to meet household energy demands [J].
Barbieri, Enrico Saverio ;
Spina, Pier Ruggero ;
Venturini, Mauro .
APPLIED ENERGY, 2012, 97 :723-733
[6]   Guidelines for residential micro-CHP systems design [J].
Bianchi, Michele ;
De Pascale, Andrea ;
Spina, Pier Ruggero .
APPLIED ENERGY, 2012, 97 :673-685
[7]   Micro-CHP systems for residential applications [J].
De Paepe, Michel ;
D'Herdt, Peter ;
Mertens, David .
ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (18-19) :3435-3446
[8]  
Department of Environment Community and Local Government, 2008, TECHN GUID DOC L
[9]  
Department of Environment Heritage and Local Government, PEOPLE POWER
[10]   Energy and CO2 emissions performance assessment of residential micro-cogeneration systems with dynamic whole-building simulation programs [J].
Dorer, Viktor ;
Weber, Andreas .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (03) :648-657