Anterior chamber depth estimation by Scheimpflug photography

被引:19
作者
Holmén, JB
Ekesten, B
Lundgren, B
机构
[1] Swedish Univ Agr Sci, Fac Vet Med, Unit Ophthalmol, SE-75007 Uppsala, Sweden
[2] Visionar Biomed AB, Uppsala, Sweden
来源
ACTA OPHTHALMOLOGICA SCANDINAVICA | 2001年 / 79卷 / 06期
关键词
anterior chamber depth; ACD; viscoelastic solution; Healon; EAS-1000; Scheimpflug; porcine eyes;
D O I
10.1034/j.1600-0420.2001.790606.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To obtain a model suitable for evaluation of the anterior chamber depth (ACD) maintaining capacity of viscoelastic substances - a critical parameter in cataract surgery. Methods: ACD was estimated using an anterior segment analysis system (EAS-1000, Nidek Co Ltd, Japan). Variation was studied as an effect of batch number and eye within batch, storage, globe fixation, globe position, and repeated analyses of Scheimpflug images. Results: Considerable variation in ACD was found between eyes, batches, and as a result of prolonged storage (biological factors). Different IOPs before surgery caused significant alterations in ACD after overfilling with a viscoelastic substance. No significant differences were found when the globe position was altered or when the ACD was re-estimated repeatedly from the same photograph. Conclusion: Differences due to biological factors are more important than methodological errors caused by the Scheimpflug instrument. To reduce these variations when viscoelastics are evaluated, all measurements should be calculated as % of ACD before surgery and the anterior chamber should be overfilled with a viscoelastic solution.
引用
收藏
页码:576 / 579
页数:4
相关论文
共 13 条
[1]  
BAEZ KA, 1992, OPHTHALMIC SURG LAS, V23, P426
[2]   ENDOTHELIAL PROTECTION AND VISCOELASTIC RETENTION DURING PHACOEMULSIFICATION AND INTRAOCULAR-LENS IMPLANTATION [J].
GLASSER, DB ;
OSBORN, DC ;
NORDEEN, JF ;
MIN, YI .
ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (10) :1438-1440
[3]   BIOMETRY OF THE ANTERIOR EYE SEGMENT BY SCHEIMPFLUG PHOTOGRAPHY [J].
HOCKWIN, O ;
WEIGELIN, E ;
LASER, H ;
DRAGOMIRESCU, V .
OPHTHALMIC RESEARCH, 1983, 15 (02) :102-108
[4]   Scheimpflug records without distortion -: A mythos? [J].
Huebscher, HJ ;
Fink, W ;
Steinbrück, D ;
Seiler, T .
OPHTHALMIC RESEARCH, 1999, 31 (02) :134-139
[5]   IMPROVED BIOMETRY OF THE ANTERIOR EYE SEGMENT [J].
KAMPFER, T ;
WEGENER, A ;
DRAGOMIRESCU, V ;
HOCKWIN, O .
OPHTHALMIC RESEARCH, 1989, 21 (03) :239-248
[6]   AUTOMATED BIOMETRY AND DENSITOGRAPHY OF ANTERIOR SEGMENT OF THE EYE [J].
LERMAN, S ;
HOCKWIN, O .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1985, 223 (03) :121-129
[7]   VISCOELASTIC SUBSTANCES IN OPHTHALMOLOGY [J].
LIESEGANG, TJ .
SURVEY OF OPHTHALMOLOGY, 1990, 34 (04) :268-293
[8]   OPTICAL PROBLEMS OF ANTERIOR-CHAMBER DEPTH BIOMETRY BY SCHEIMPFLUG PHOTOGRAPHY [J].
OLBERT, D .
OPHTHALMIC RESEARCH, 1991, 23 (06) :342-347
[9]   New method to measure the retention of viscoelastic agents on a rabbit corneal endothelial cell line after irrigation and aspiration [J].
Poyer, JF ;
Chan, KY ;
Arshinoff, SA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (01) :84-90
[10]   Quantitative method to determine the cohesion of viscoelastic agents by dynamic aspiration [J].
Poyer, JF ;
Chan, KY ;
Arshinoff, SA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (08) :1130-1135