Salmonella typhi determination using voltammetric amplification of nanoparticles: A highly sensitive strategy for metalloimmunoassay based on a copper-enhanced gold label

被引:53
作者
Dungchai, Wijitar [1 ]
Siangproh, Weena [2 ]
Chaicumpa, Wanpen [3 ]
Tongtawe, Pongsri [4 ]
Chailapakul, Orawon [1 ]
机构
[1] Chulalongkorn Univ, Fac Sci, Sensor Res Unit, Dept Chem, Bangkok 10330, Thailand
[2] Srinakharinwirot Univ, Fac Sci, Dept Chem, Bangkok 10110, Thailand
[3] Mahidol Univ, Siriraj Hosp, Fac Med, Dept Parasitol, Bangkok 10700, Thailand
[4] Thammasat Univ, Fac Allied Hlth Sci, Pathum Thani 12120, Thailand
关键词
Electrochemical immunoassay; Gold nanoparticles; Copper-enhancer solution; Salmonella typhi;
D O I
10.1016/j.talanta.2008.07.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive electrochemical amplification immunoassay for Salmonella typhi (S. typhi) determination has been developed for the first time by using a copper-enhanced gold nanoparticle label coupled with anodic stripping voltammetry. Monoclonal antibodies for S. typhi were first immobilized oil polystyrene microwells and then Captured by S. typhi bacteria. After an immunoreaction occurred, a polyclonal, antibody-colloidal gold Conjugate was added to bind to the S. typhi bacteria. Next, a copper-enhancer Solution containing ascorbic acid and copper (II) Sulfate was added into the polystyrene microwells. The ascorbic acid was employed to reduce the copper(II) ions to copper(0), which Was Subsequently deposited onto the gold nanoparticle tags. After the copper was dissolved in nitric acid, the released copper ions were detected by anodic stripping voltammetry. The amount of deposited copper was related to the amount of gold nanoparticle tag present, which was controlled by the amount S. typhi attached to the polyclonal antibody-colloidal gold conjugate. Therefore, the anodic stripping peak Current was linearly dependent on the S. typhi concentration over concentration range of 1.30 x 10(2) cfu/mL to 2.6 x 10(3) cfu/mL in a logarithmic plot, with a detection limit as low as 98.9 cfu/mL. The influences of the relevant experimental variables, such as the concentration of copper and the reaction time of S. typhi with antibody, were investigated. We also Successfully applied this method to determine the presence of S. typhi in human serum. Our results are a step towards developing more sensitive and reliable nanoparticle immunoassays. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:727 / 732
页数:6
相关论文
共 24 条
[1]   DIAGNOSIS OF TYPHOID-FEVER BY DETECTION OF SALMONELLA-TYPHI ANTIGEN IN URINE [J].
CHAICUMPA, W ;
RUANGKUNAPORN, Y ;
BURR, D ;
CHONGSANGUAN, M ;
ECHEVERRIA, P .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (09) :2513-2515
[2]  
Chaicumpa W, 1995, ASIAN PAC J ALLERGY, V13, P159
[3]   An electrochemical stripping metalloimmunoassay based on silver-enhanced gold nanoparticle label [J].
Chu, X ;
Fu, X ;
Chen, K ;
Shen, GL ;
Yu, RQ .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (09) :1805-1812
[4]  
*DEP HLTH HUM SERV, 2005, TYPH FEV
[5]   An electrochemical metalloimmunoassay based on a colloidal gold label [J].
Dequaire, M ;
Degrand, C ;
Limoges, B .
ANALYTICAL CHEMISTRY, 2000, 72 (22) :5521-5528
[6]   Real-time PCR for the detection of Salmonella spp. in food:: An alternative approach to a conventional PCR system suggested by the FOOD-PCR project [J].
Hein, Ingeborg ;
Flekna, Gabriele ;
Krassnig, Martina ;
Wagner, Martin .
JOURNAL OF MICROBIOLOGICAL METHODS, 2006, 66 (03) :538-547
[7]   Evaluation of culture enrichment procedures for use with Salmonella detection immunoassay [J].
Huang, HS ;
Garcia, MM ;
Brooks, BW ;
Nielsen, K ;
Ng, SP .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 1999, 51 (2-3) :85-94
[8]   Immobilization of antibodies and bacterial binding on nanodiamond and carbon nanotubes for biosensor applications [J].
Huang, TS ;
Tzeng, Y ;
Liu, YK ;
Chen, YK ;
Walker, KR ;
Guntupalli, R ;
Liu, C .
DIAMOND AND RELATED MATERIALS, 2004, 13 (4-8) :1098-1102
[9]  
IVANOFF B, 1994, B WORLD HEALTH ORGAN, V72, P957
[10]  
KATHERINE C, 1995, ANAL CHEM, V67, P735