D-dimer and anticoagulation in patients with mechanical prosthetic heart valves - A 2-year follow-up

被引:16
作者
Giansante, C
Fiotti, N
Calabrese, S
LaVerde, R
Pandullo, C
Scardi, S
Guarnieri, G
机构
[1] UNIV TRIESTE,INST CLIN MED,TRIESTE,ITALY
[2] OSPED MAGGIORE TRIESTE,CTR CARDIOVASC,TRIESTE,ITALY
关键词
fibrin degradation products; oral anticoagulants; thromboembolism; hemorrhage;
D O I
10.1161/01.ATV.17.7.1320
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The best anticoagulation level in patients with mechanical heart valve prostheses is still being debated. D-dimer, which detects the presence of cross-linked fibrin degradation products, has been demonstrated to be: a useful marker of coagulation activation. This study was designed to verify whether heart valve prostheses in anticoagulated patients are associated with abnormalities in D-dimer plasma levels, and if so, whether such levels are related to the anticoagulation level and/or whether they could be predictive of acute vascular or hemorrhagic events. In 132 patients with single and 10 with double mechanical valve replacement, international normalized ratio (INR) and D-dimer plasma levels were determined. The INR levels of the previous 8 months were reviewed to assess the time that each patient spent in the therapeutic range. The D-dimer plasma levels were compared with those obtained from 102 matched control subjects. The patients were then followed up for 2 years to record acute vascular and hemorrhagic events. For the entire group, D-dimer plasma levels in patients were the same as those in the control group. Patients with double valve replacement had higher D-dimer plasma levels than either monovalvular implant patients or control subjects. Patients who had spent <75% of the time within the assigned anticoagulation range had higher values far D-dimer plasma levels (median, 270 vs 198 ng/mL, P=.02). The major determinants of D-dimer plasma levels were age (R-2=.07, P=.009) and the percentage of time spent below the predetermined INR level (R-2=.09, P=.001). During follow-up, 19 acute vascular and 16 hemorrhagic events occurred. High D-dimer tertile was the only parameter predicting the occurrence of thromboembolic events. In patients with mechanical heart valve prostheses, the D-dimer plasma level depended on the thoroughness of anticoagulation. Patients in the upper tertile of D-dimer values have an approximate to 5-fold risk of vascular thromboembolic events. D-dimer determination can therefore be useful in detecting patients who are at a higher risk of severe vascular events.
引用
收藏
页码:1320 / 1324
页数:5
相关论文
共 21 条
[1]  
ALTMAN R, 1991, J THORAC CARDIOV SUR, V101, P427
[2]  
BOISCLAIR MD, 1993, THROMB HAEMOSTASIS, V70, P253
[3]  
BOUNAMEAUX H, 1994, THROMB HAEMOSTASIS, V71, P1
[4]   OPTIMAL ORAL ANTICOAGULANT-THERAPY IN PATIENTS WITH MECHANICAL HEART-VALVES [J].
CANNEGIETER, SC ;
ROSENDAAL, FR ;
WINTZEN, AR ;
VANDERMEER, FJM ;
VANDENBROUCKE, JP ;
BRIET, E .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 333 (01) :11-17
[5]  
CORTELAZZO S, 1993, THROMB HAEMOSTASIS, V69, P316
[6]  
CRISCITIELLO MG, 1992, HOSP PRACT, V27, P69
[7]   THROMBOTIC AND BLEEDING COMPLICATIONS OF PROSTHETIC HEART-VALVES [J].
EDMUNDS, LH .
ANNALS OF THORACIC SURGERY, 1987, 44 (04) :430-445
[8]  
GIANSANTE C, 1994, THROMB HAEMOSTASIS, V71, P581
[9]   COAGULATION-FACTORS AND THE INCREASED RISK OF STROKE IN NONVALVULAR ATRIAL-FIBRILLATION [J].
GUSTAFSSON, C ;
BLOMBACK, M ;
BRITTON, M ;
HAMSTEN, A ;
SVENSSON, J .
STROKE, 1990, 21 (01) :47-51
[10]  
Hayashi I, 1993, J Cardiol, V23, P177