Sonoelectroanalysis: investigation of bismuth-film-modified glassy carbon electrodes

被引:51
作者
Banks, CE [1 ]
Kruusma, J [1 ]
Hyde, ME [1 ]
Salimi, A [1 ]
Compton, RG [1 ]
机构
[1] Univ Oxford, Phys Chem Lab, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
关键词
sonoelectroanalysis; bismuth film; ultrasound; stripping voltammetry; zinc; cadmium;
D O I
10.1007/s00216-004-2553-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bismuth-modified glassy carbon electrodes have been investigated for their suitability in sonoelectroanalysis. The stability of the bismuth film to the application of ultrasound was assessed via voltammetric and atomic force microscopy (AFM) studies which revealed little ablation at powers up to an intensity of 130 W cm(-2) delivered from a 25-kHz sonic horn. Furthermore, bismuth-film-modified glassy carbon electrodes were evaluated for the sonoelectroanalytical quantification of zinc and cadmium. Detection limits of 2x10(-7) M and 6x10(-9) M respectively were found after a 60-s deposition time via an acoustically assisted deposition protocol.
引用
收藏
页码:277 / 282
页数:6
相关论文
共 31 条
[1]   Voltammetric determination of niclosamide at a glassy carbon electrode [J].
Alemu, H ;
Wagana, P ;
Tseki, PF .
ANALYST, 2002, 127 (01) :129-134
[2]   Ultrasonically enhanced voltammetric analysis and applications: An overview [J].
Banks, CE ;
Compton, RG .
ELECTROANALYSIS, 2003, 15 (5-6) :329-346
[3]   Voltammetric exploration and applications of ultrasonic cavitation [J].
Banks, CE ;
Compton, RG .
CHEMPHYSCHEM, 2003, 4 (02) :169-178
[4]  
BANKS CE, 2003, UNPUB
[5]   Stability of mercury film electrodes under the influence of high frequency (500 kHz) ultrasound [J].
Davis, J ;
Del Campo, FJ ;
Marken, F ;
Compton, RG ;
Cordemans, E .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2001, 31 (04) :475-480
[6]   Mercury film electrodes: developments, trends and potentialities for electroanalysis [J].
Economou, A ;
Fielden, PR .
ANALYST, 2003, 128 (03) :205-212
[7]   Anodic stripping voltammetry of lead and cadmium using a mercury film electrode and thiocyanate [J].
Fischer, E ;
van den Berg, CMG .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :273-280
[8]   Electron transfer kinetics of ferrocene at microcrystalline boron-doped diamond electrodes: Effect of solvent and electrolyte [J].
Haymond, S ;
Babcock, GT ;
Swain, GM .
ELECTROANALYSIS, 2003, 15 (04) :249-253
[9]   A study on operational parameters for advanced use of bismuth film electrode in anodic stripping voltammetry [J].
Hocevar, SB ;
Ogorevc, B ;
Wang, J ;
Pihlar, B .
ELECTROANALYSIS, 2002, 14 (24) :1707-1712
[10]  
Hocevar SB, 2002, ELECTROANAL, V14, P112, DOI 10.1002/1521-4109(200201)14:2<112::AID-ELAN112>3.0.CO