Simple, rapid determination of enrofloxacin and ciprofloxacin in bovine milk and plasma by high-performance liquid chromatography with fluorescence detection

被引:150
作者
Idowu, OR [1 ]
Peggins, JO [1 ]
机构
[1] US FDA, Ctr Vet Med, Laurel, MD 20708 USA
关键词
enrofloxacin; ciprofloxacin; bovine milk; bovine plasma; HPLC;
D O I
10.1016/j.jpba.2004.01.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and simple procedure for determination of enrofloxacin and ciprofloxacin in bovine milk and plasma is described. Protein precipitation from both milk and plasma samples was achieved by addition of acetonitrile and phosphoric acid. Acetonitrile was removed with methylene chloride, leaving enrofloxacin and ciprofloxacin in the acidic aqueous extract. The aqueous extract was analyzed by high-performance liquid chromatography (HPLC) with fluorescence detection. The limit of quantitation (LOQ) for enrofloxacin and ciprofloxacin in milk was found to be 2 ng/ml. LOQ for enrofloxacin and ciprofloxacin in plasma was found to be I ng/ml. Linear calibration curves were obtained with correlation coefficient (r(2)) greater than or equal to0.99. Analysis of quality control (QC) samples gave results within +/-10% of the nominal values. Inter-assay precision for the analysis of milk QC samples were in the ranges: 4.63-12.49% (for enrofloxacin) and 4.67-9.86% (for ciprofloxacin). Inter-assay precision for the analysis of plasma QC samples were in the ranges: 6.60-17.31% (for enrofloxacin) and 6.14-13.87% (for ciprofloxacin). Intra-assay precision for the analysis of milk QC samples were in the following ranges: 3.65-7.21% (for enrofloxacin) and 1.58-14.28% (for ciprofloxacin). Intra-assay precision for the analysis of plasma QC samples were in the following ranges: 2.17-16.95% (for enrofloxacin) and 3.31-16.31% (for ciprofloxacin). The effectiveness of protein precipitants other than phosphoric acid was investigated. The method described has been applied to a study of the pharmacokinetics of enrofloxacin and ciprofloxacin in lactating dairy cows and beef steers. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:143 / 153
页数:11
相关论文
共 28 条
  • [1] Ciprofloxacin pharmacokinetics in dogs following oral administration
    Abadia, AR
    Aramayona, JJ
    Munoz, MJ
    Delfina, JMP
    Bregante, MA
    [J]. JOURNAL OF VETERINARY MEDICINE SERIES A-PHYSIOLOGY PATHOLOGY CLINICAL MEDICINE, 1995, 42 (08): : 505 - 511
  • [2] Bauditz R., 1987, Veterinary Medical Review, German Federal Republic, P122
  • [3] COMPARISON OF HIGH-PRESSURE LIQUID-CHROMATOGRAPHY AND MICROBIOLOGICAL ASSAY FOR THE DETERMINATION OF BILIARY ELIMINATION OF CIPROFLOXACIN IN HUMANS
    BROGARD, JM
    JEHL, F
    MONTEIL, H
    ADLOFF, M
    BLICKLE, JF
    LEVY, P
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1985, 28 (02) : 311 - 314
  • [4] Fluoroquinolones in animal health
    Brown, SA
    [J]. JOURNAL OF VETERINARY PHARMACOLOGY AND THERAPEUTICS, 1996, 19 (01) : 1 - 14
  • [5] CIPROFLOXACIN - A REVIEW OF ITS ANTIBACTERIAL ACTIVITY, PHARMACOKINETIC PROPERTIES AND THERAPEUTIC USE
    CAMPOLIRICHARDS, DM
    MONK, JP
    PRICE, A
    BENFIELD, P
    TODD, PA
    WARD, A
    [J]. DRUGS, 1988, 35 (04) : 373 - 447
  • [6] Analysis of fluoroquinolones in biological fluids by high-performance liquid chromatography
    Carlucci, G
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) : 343 - 367
  • [7] INTRAMUSCULAR AND ORAL DISPOSITION OF ENROFLOXACIN IN AFRICAN GRAY PARROTS FOLLOWING SINGLE AND MULTIPLE DOSES
    FLAMMER, K
    AUCOIN, DP
    WHITT, DA
    [J]. JOURNAL OF VETERINARY PHARMACOLOGY AND THERAPEUTICS, 1991, 14 (04) : 359 - 366
  • [8] Determination of marbofloxacin in plasma samples by high-performance liquid chromatography using fluorescence detection
    Garcia, MA
    Solans, C
    Aramayona, JJ
    Rueda, S
    Bregante, MA
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1999, 729 (1-2): : 157 - 161
  • [9] Garcia MA, 1999, BIOMED CHROMATOGR, V13, P350, DOI 10.1002/(SICI)1099-0801(199908)13:5<350::AID-BMC889>3.0.CO
  • [10] 2-C