Fluorescent Silica Nanoparticles Improve Optical Imaging of Stem Cells Allowing Direct Discrimination between Live and Early-Stage Apoptotic Cells

被引:40
作者
Accomasso, Lisa [1 ]
Rocchietti, Elisa Cibrario [1 ]
Raimondo, Stefania [1 ]
Catalano, Federico [2 ]
Alberto, Gabriele [2 ]
Giannitti, Andrea [2 ]
Minieri, Valentina [1 ]
Turinetto, Valentina [1 ]
Orlando, Luca [1 ]
Saviozzi, Silvia [1 ]
Caputo, Giuseppe [2 ]
Geuna, Stefano [1 ]
Martra, Gianmario [2 ]
Giachino, Claudia [1 ]
机构
[1] Univ Turin, Dept Clin & Biol Sci, I-10043 Turin, Italy
[2] Univ Turin, Dept Chem, Interdept Ctr Excellence Nanostruct Interfaces &, I-10125 Turin, Italy
关键词
apoptosis; biocompatible materials; imaging; nanoparticles; stem cells; MESENCHYMAL STROMAL CELLS; ANNEXIN-V; ASSAY; DIFFERENTIATION; CYTOTOXICITY; LYMPHOCYTES; SPECT;
D O I
10.1002/smll.201200882
中图分类号
O6 [化学];
学科分类号
070301 [无机化学];
摘要
Highly bright and photostable cyanine dye-doped silica nanoparticles, IRIS Dots, are developed, which can efficiently label human mesenchymal stem cells (hMSCs). The application procedure used to label hMSCs is fast (2 h), the concentration of IRIS Dots for efficient labeling is low (20 mu g mL-1), and the labeled cells can be visualized by flow cytometry, confocal microscopy, and transmission electron microscopy. Labeled hMSCs are unaffected in their viability and proliferation, as well as stemness surface marker expression and differentiation capability into osteocytes. Moreover, this is the first report that shows nonfunctionalized IRIS Dots can discriminate between live and early-stage apoptotic stem cells (both mesenchymal and embryonic) through a distinct external cell surface distribution. On the basis of biocompatibility, efficient labeling, and apoptotic discrimination potential, it is suggested that IRIS Dots can serve as a promising stem cell tracking agent.
引用
收藏
页码:3192 / 3200
页数:9
相关论文
共 42 条
[1]
Hybrid Cyanine-Silica Nanoparticles: Homogeneous Photoemission Behavior of Entrapped Fluorophores and Consequent High Brightness Enhancement [J].
Alberto, Gabriele ;
Miletto, Ivana ;
Viscardi, Guido ;
Caputo, Giuseppe ;
Latterini, Loredana ;
Coluccia, Salvatore ;
Martra, Gianmario .
JOURNAL OF PHYSICAL CHEMISTRY C, 2009, 113 (50) :21048-21053
[2]
Superparamagnetic Iron Oxide Nanoparticles Labeling of Bone Marrow Stromal (Mesenchymal) Cells Does Not Affect Their "Stemness'' [J].
Balakumaran, Arun ;
Pawelczyk, Edyta ;
Ren, Jiaqiang ;
Sworder, Brian ;
Chaudhry, Aneeka ;
Sabatino, Marianna ;
Stroncek, David ;
Frank, Joseph A. ;
Robey, Pamela G. .
PLOS ONE, 2010, 5 (07)
[3]
Phospholipid scramblase: An update [J].
Bevers, Edouard M. ;
Williamson, Patrick L. .
FEBS LETTERS, 2010, 584 (13) :2724-2730
[4]
Labelling of human mesenchymal stem cells with indium-111 for SPECT imaging:: effect on cell proliferation and differentiation [J].
Bindslev, L. ;
Haack-Sorensen, M. ;
Bisgaard, K. ;
Kragh, L. ;
Mortensen, S. ;
Hesse, B. ;
Kjaer, A. ;
Kastrup, J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (10) :1171-1177
[5]
Luminescent Chemosensors Based on Silica Nanoparticles [J].
Bonacchi, Sara ;
Genovese, Damiano ;
Juris, Riccardo ;
Montalti, Marco ;
Prodi, Luca ;
Rampazzo, Enrico ;
Sgarzi, Massimo ;
Zaccheroni, Nelsi .
LUMINESCENCE APPLIED IN SENSOR SCIENCE, 2011, 300 :93-138
[6]
Luminescent Silica Nanoparticles: Extending the Frontiers of Brightness [J].
Bonacchi, Sara ;
Genovese, Damiano ;
Juris, Riccardo ;
Montalti, Marco ;
Prodi, Luca ;
Rampazzo, Enrico ;
Zaccheroni, Nelsi .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2011, 50 (18) :4056-4066
[7]
In vivo MR imaging of intravascularly injected magnetically labeled mesenchymal stem cells in rat kidney and liver [J].
Bos, C ;
Delmas, Y ;
Desmoulière, A ;
Solanilla, A ;
Hauger, O ;
Grosset, C ;
Dubus, I ;
Ivanovic, Z ;
Rosenbaum, J ;
Charbord, P ;
Combe, C ;
Bulte, JWM ;
Moonen, CTW ;
Ripoche, J ;
Grenier, N .
RADIOLOGY, 2004, 233 (03) :781-789
[8]
A NONISOTOPIC, HIGHLY SENSITIVE, FLUOROMETRIC, CELL-CELL ADHESION MICROPLATE ASSAY USING CALCEIN AM-LABELED LYMPHOCYTES [J].
BRAUTBOUCHER, F ;
PICHON, J ;
RAT, P ;
ADOLPHE, M ;
AUBERY, M ;
FONT, J .
JOURNAL OF IMMUNOLOGICAL METHODS, 1995, 178 (01) :41-51
[9]
A simple protocol for paraffin-embedded myelin sheath staining with osmium tetroxide for light microscope observation [J].
Di Scipio, Federica ;
Raimondo, Stefania ;
Tos, Pierluigi ;
Geuna, Stefano .
MICROSCOPY RESEARCH AND TECHNIQUE, 2008, 71 (07) :497-502
[10]
Cytotoxicity of 111In-oxine on mesenchymal stem cells: a time-dependent adverse effect [J].
Gholamrezanezhad, Ali ;
Mirpour, Sahar ;
Ardekani, Jalil Majd ;
Bagheri, Mohammad ;
Alimoghadam, Kamran ;
Yarmand, Sarah ;
Malekzadeh, Reza .
NUCLEAR MEDICINE COMMUNICATIONS, 2009, 30 (03) :210-216