Integrated assessment of combined cooling heating and power systems under different design and management options for residential buildings in Shanghai

被引:68
作者
Gu, Qunyin [1 ,2 ]
Ren, Hongbo [3 ]
Gao, Weijun [2 ]
Ren, Jianxing [4 ]
机构
[1] Shanghai Univ Elect Power, Inst Elect Power & Automat Engn, Shanghai 200090, Peoples R China
[2] Univ Kitakyushu, Fac Environm Engn, Kitakyushu, Fukuoka 8080135, Japan
[3] Ritsumeikan Univ, Ritsumeikan Global Innovat Res Org, Kyoto 6038577, Japan
[4] Shanghai Univ Elect Power, Inst Energy & Environm Engn, Shanghai 200090, Peoples R China
关键词
Integrated assessment; Combined cooling heating and power (CCHP); Residential building; Heat tracking (HT); Electricity tracking (ET); Energy island (EI); DIFFERENT CLIMATE ZONES; BCHP SYSTEM; ENERGY; OPTIMIZATION; PERFORMANCE; IMPACT;
D O I
10.1016/j.enbuild.2012.04.023
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As a well-known technique for rational use of energy, the combined cooling, heating and power (CCHP) system is paid more and more attention in building energy conservation activities. In this paper, the performances of typical CCHP systems are investigated for a high-rise residential building, which is experiencing rapid expansion in China. Based on the building's energy consumption, four types of CCHP technologies have been assumed following three design and management modes, namely, heat tracking mode, electricity tracking mode and energy island mode. In order to have a comprehensive understanding of the performance of the assumed CCHP systems, besides the separated energy, economic and environmental assessments, an integrated assessment framework is proposed. According to the simulation results, gas engine and fuel cell based CCHP systems are feasible options from the energy and environmental viewpoints, but at the cost of poor economic performance. From an integrated viewpoint, the gas engine system is the most attractive option if economic performance is taken into account; otherwise the fuel cell system is the best choice. In addition, the selection of proper design and management mode is of vital importance for the adoption of the CCHP system. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:143 / 152
页数:10
相关论文
共 29 条
[1]  
[Anonymous], 2006, BUILDING ENV SYSTEM
[2]   China building energy consumption: Situation, challenges and corresponding measures [J].
Cai, W. G. ;
Wu, Y. ;
Zhong, Y. ;
Ren, H. .
ENERGY POLICY, 2009, 37 (06) :2054-2059
[3]   Simulation and optimization of the performance in the air-conditioning season of a BCHP system in China [J].
Cao, Jia-cong ;
Liu, Feng-qiang .
ENERGY AND BUILDINGS, 2008, 40 (03) :185-192
[4]   A methodology for sizing a trigeneration plant in mediterranean areas [J].
Cardona, E ;
Piacentino, A .
APPLIED THERMAL ENGINEERING, 2003, 23 (13) :1665-1680
[5]   Statistical analyses on summer energy consumption characteristics of residential buildings in some cities of China [J].
Chen, Shuqin ;
Yoshino, Hiroshi ;
Li, Nianping .
ENERGY AND BUILDINGS, 2010, 42 (01) :136-146
[6]  
Delta Energy and Environment, 2006, NEW TECHN CHP APPL
[7]  
Firestone Ryan., 2004, Distributed Energy Resources Customer Adoption Model Technology Data"
[8]   Cooling, heating, and power energy performance for system feasibility [J].
Fumo, N. ;
Mago, P. J. ;
Chamra, L. M. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2008, 222 (A4) :347-354
[9]   The impact of thermal storage on the operational behaviour of residential CHP facilities and the overall CO2 emissions [J].
Haeseldonckx, Dries ;
Peeters, Leen ;
Helsen, Lieve ;
D'haeseleer, William .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2007, 11 (06) :1227-1243
[10]   Role of BCHP in energy and environmental sustainable development and its prospects in China [J].
Hao, Xiaoli ;
Zhang, Guoqiang ;
Chen, Youming .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2007, 11 (08) :1827-1842