Comparison of simultaneous measurement of mouse systolic arterial blood pressure by radiotelemetry and tail-cuff methods

被引:180
作者
Whitesall, SE
Hoff, JB
Vollmer, AP
D'Alecy, LG
机构
[1] Univ Michigan, Sch Med, Dept Mol & Integrat Physiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Sch Med, Dept Vasc Surg, Ann Arbor, MI 48109 USA
[3] William Beaumont Hosp, Dept Surg, Royal Oak, MI 48073 USA
[4] Ann Arbor Healthcare Syst, Vet Adm, Ann Arbor, MI 48105 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2004年 / 286卷 / 06期
关键词
rodent blood pressure; indirect and direct blood pressure measurement; technique;
D O I
10.1152/ajpheart.01089.2003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Radiotelemetry of mouse blood pressure accurately monitors systolic pressure, diastolic pressure, heart rate, and locomotor activity but requires surgical implantation. Noninvasive measurements of indirect systolic blood pressure have long been available for larger rodents and now are being reported more frequently for mice. This study compared mouse systolic arterial blood pressure measurements using implanted radiotelemetry pressure transducer with simultaneous tail-cuff measurements in the same unanesthetized mice. The pressure range for comparison was extended by inducing experimental hypertension or by observations of circadian elevations between 3 AM and 6 AM. Both trained and untrained tail-cuff operators used both instruments. Every effort was made to follow recommended manufacturer's instructions. With the initial flow-based tail-cuff instrument, we made 671 comparisons (89 sessions) and found the slope of the linear regression to be 0.118, suggesting poor agreement. In an independent assessment, 277 comparisons (35 sessions) of radiotelemetry measurements with the pulse based tail-cuff instrument were made. The slope of the linear regression of the simultaneous measurements of systolic pressures was 0.98, suggesting agreement. Bland-Altman analysis also supported our interpretation of the linear regression. Thus although reliable systolic pressure measurements are possible with either tail-cuff or radiotelemetry techniques, in our hands some tail-cuff instruments fail to accurately detect elevated blood pressures. These data, however, do not distinguish whether this instrument-specific tail-cuff failure was due to operator or instrument inadequacies. We strongly advise investigators to obtain an independent and simultaneous validation of tail-cuff determinations of mouse blood pressure before making critical genotyping determinations.
引用
收藏
页码:H2408 / H2415
页数:8
相关论文
共 18 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Long-term telemetric measurement of cardiovascular parameters in awake mice: a physiological genomics tool [J].
Butz, GM ;
Davisson, RL .
PHYSIOLOGICAL GENOMICS, 2001, 5 (02) :89-97
[5]   Long-term telemetric recording of arterial pressure and heart rate in mice fed basal and high NaCl diets [J].
Carlson, SH ;
Wyss, JM .
HYPERTENSION, 2000, 35 (02) :E1-+
[6]   Exercising restraint in measuring blood pressure in conscious mice [J].
Gross, V ;
Luft, FC .
HYPERTENSION, 2003, 41 (04) :879-881
[7]   Models of experimental hypertension in mice [J].
Johns, C ;
Gavras, I ;
Handy, DE ;
Salomao, A ;
Gavras, H .
HYPERTENSION, 1996, 28 (06) :1064-1069
[8]   Evaluation and applications of radiotelemetry in small laboratory animals [J].
Kramer, K ;
Kinter, LB .
PHYSIOLOGICAL GENOMICS, 2003, 13 (03) :197-205
[9]  
Kramer K, 2001, CONTEMP TOP LAB ANIM, V40, P8
[10]   Telemetric monitoring of blood pressure in freely moving mice: a preliminary study [J].
Kramer, K ;
Voss, HP ;
Grimbergen, JA ;
Mills, PA ;
Huetteman, D ;
Zwiers, L ;
Brockway, B .
LABORATORY ANIMALS, 2000, 34 (03) :272-280