Unattended continuous positive airway pressure titration - Clinical relevance and cardiorespiratory hazards of the method

被引:25
作者
Juhasz, J [1 ]
Schillen, J [1 ]
Urbigkeit, A [1 ]
Ploch, T [1 ]
Penzel, T [1 ]
Peter, JH [1 ]
机构
[1] KORANYI NATL INST PULM MED,RESP CARE UNIT,BUDAPEST,HUNGARY
关键词
D O I
10.1164/ajrccm.154.2.8756807
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The high cost of in-laboratory sleep studies and the insufficiency of available nights in most sleep laboratories has prompted clinical trials in an attempt to find an effective and safe method for continuous positive airway pressure (CPAP) titration in the unsupervised home environment. Earlier publications focused on the effectiveness of this new method but did not indicate the potential hazard and the selection criteria of patients. We accomplished a prospective study to evaluate a machine-controlled CPAP titration method in an unselected group of 21 patients with obstructive sleep apnea (OSA) requiring CPAP therapy. Unattended CPAP titrations were completed in the sleep laboratory, followed by conventional CPAP titration night. The CPAP levels assessed through automatic titrations showed strong agreement with those from the control nights. Fifteen patients had no pathologic cardiorespiratory events during machine-controlled titration. Undesirable cardiorespiratory complications developed in six patients with underlying cardiorespiratory disorder. Two patients had to stop the procedure. Two patients needed a reset of the actual pressure to baseline because of central apneas and one patient because of high-grade arrhythmia. The machine-controlled CPAP titration enabled reliable assessment of an effective pressure and appeared to be safe in selected patients with OSA. However, because the method caused significant adverse effects in some patients, we recommend that unattended CPAP titration not be attempted in patients with underlying cardiorespiratory disease.
引用
收藏
页码:359 / 365
页数:7
相关论文
共 31 条
[1]   EFFECTS OF CONTINUOUS POSITIVE AIRWAY PRESSURE ON PHASIC EVENTS OF REM-SLEEP IN PATIENTS WITH OBSTRUCTIVE SLEEP-APNEA [J].
ALDRICH, M ;
EISER, A ;
LEE, M ;
SHIPLEY, JE .
SLEEP, 1989, 12 (05) :413-419
[2]  
BECKER H, 1987, SLEEP RELATED DISORD, P380
[3]  
BECKER H, 1992, EUR RESPIR J, V2, P400
[4]  
BERTHONJONES M, 1993, SLEEP, V16, P120
[5]  
BURK JR, 1992, SLEEP RES, V21, P182
[6]   FLOW LIMITATION AS A NONINVASIVE ASSESSMENT OF RESIDUAL UPPER-AIRWAY RESISTANCE DURING CONTINUOUS POSITIVE AIRWAY PRESSURE THERAPY OF OBSTRUCTIVE SLEEP-APNEA [J].
CONDOS, R ;
NORMAN, RG ;
KRISHNASAMY, I ;
PEDUZZI, N ;
GOLDRING, RM ;
RAPOPORT, DM .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 150 (02) :475-480
[7]   MANAGEMENT OF OBSTRUCTIVE SLEEP-APNEA SYNDROME IN THE HOME - THE ROLE OF PORTABLE SLEEP-APNEA RECORDING [J].
COPPOLA, MP ;
LAWEE, M .
CHEST, 1993, 104 (01) :19-25
[8]  
Davies W. L., 1994, Journal of Sleep Research, V3, P57
[9]  
GUILLEMINAULT C, 1992, American Review of Respiratory Disease, V145, pA725
[10]   THE IMMEDIATE EFFECTS OF NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE TREATMENT ON SLEEP PATTERN IN PATIENTS WITH OBSTRUCTIVE SLEEP-APNEA SYNDROME [J].
ISSA, FG ;
SULLIVAN, CE .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1986, 63 (01) :10-17