Thoracic aortic operations: Management of maldistribution of arterial flow during cardiopulmonary bypass

被引:1
作者
Najafi, H
Veeragandham, R
机构
[1] RUSH MED COLL,DEPT CARDIOVASC THORAC SURG,CHICAGO,IL
[2] RUSH MED COLL,RUSH HEART INST,CHICAGO,IL
[3] RUSH PRESBYTERIAN ST LUKES MED CTR,CHICAGO,IL 60612
关键词
D O I
10.1016/S0003-4975(97)00446-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
On three occasions during operations for aortic aneurysm involving the ascending aorta it was noted that upon the release of the aortic clamp the grafted segment remained collapsed, indicating very little or no flow reaching the lumen of the reconstructed aorta. This was promptly and successfully remedied in 2 patients by perfusing the graft directly with a pediatric arterial catheter attached to a pump head while the femoral arterial line maintained systemic arterial inflow. This simple, safe, and highly effective technique adds to the surgeon's repertoire to manage yet another intriguing intraoperative development during thoracic aortic operations. (C) 1997 by The Society of Thoracic Surgeons.
引用
收藏
页码:565 / 567
页数:3
相关论文
共 4 条
[1]  
Borst H G, 1991, Semin Thorac Cardiovasc Surg, V3, P238
[2]   TRANSESOPHAGEAL DOPPLER-ECHOCARDIOGRAPHIC MONITORING FOR MALPERFUSION DURING AORTIC DISSECTION REPAIR [J].
NEUSTEIN, SM ;
LANSMAN, SL ;
QUINTANA, CS ;
SURIANI, R ;
ERGIN, A ;
GRIEPP, RB .
ANNALS OF THORACIC SURGERY, 1993, 56 (02) :358-361
[3]   OBSTRUCTION OF THE TRUE LUMEN DURING RETROGRADE PERFUSION OF TYPE-I AORTIC DISSECTIONS - A SIMPLIFIED SOLUTION [J].
PARR, GVS ;
MANLEY, NJ ;
WILLIAMS, DR ;
MONTESANO, RM .
ANNALS OF THORACIC SURGERY, 1980, 30 (05) :495-498
[4]  
ROBICSEK F, 1985, J CARDIOVASC SURG, V26, P36