Evaluation of a testing method for the fatigue performance of total knee tibial trays

被引:28
作者
Ahir, SP [1 ]
Blunn, GW [1 ]
Haider, H [1 ]
Walker, PS [1 ]
机构
[1] UCL, Royal Natl Orthopaed Hosp Trust, Ctr Biomed Engn, Stanmore HA7 4LP, Middx, England
关键词
tibial tray; fracture; finite element analysis; knee replacement; testing methods;
D O I
10.1016/S0021-9290(99)00094-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Catastrophic failure of tibial baseplates due to fatigue fracture have occurred in patients. The International Standards Organisation (ISO) have proposed an endurance test to ensure a safety level for trays with respect to this problem. At present the magnitude of the applied load has not been defined. The purpose of this study is to evaluate the ISO test by comparing the results of two tibial trays: one with a clinical history of fracture of the tibial baseplate in some cases (Kinematic) and one without such a record (Kinemax). A load of 2000 N was selected, representing the peak force during the normal walking cycle. Finite element analysis (FEA) predicted that both the Kinematic and Kinemax trays would rapidly fail for two defined contact positions. Mechanical testing performed on both these components confirmed the FEA predictions. However, under service conditions, the Kinematic tray has been reported to have a failure of only 1-2%, the failure occurring at a mean of 54 months for early fracture and 7 years for late fracture. There are no published reports of failed Kinemax trays. It is concluded that the ISO test is an exaggeration of reality when a physiological load is used. As a result of our study we propose that a load of 500 N would effectively screen components with respect to the ISO test conditions for the likelihood of fracture. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1049 / 1057
页数:9
相关论文
共 14 条
[1]
Fracture of the metal tibial tray after kinematic total knee replacement - A common cause of early aseptic failure [J].
Abernethy, PJ ;
Robinson, CM ;
Fowler, RM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (02) :220-225
[2]
CHEN F, 1994, CLIN ORTHOP RELAT R, P249
[3]
Fatigue integrity test of a modular tibial stem extension [J].
Cooper, MB ;
Anthony, ME ;
Salehi, AB ;
Holbrook, JA .
MODULARITY OF ORTHOPEDIC IMPLANTS, 1997, 1301 :137-145
[4]
FRACTURE OF THE TIBIAL TRAY OF THE PCA KNEE - A CASE-REPORT OF EARLY FAILURE CAUSED BY IMPROPER DESIGN [J].
FLIVIK, G ;
LJUNG, P ;
RYDHOLM, U .
ACTA ORTHOPAEDICA SCANDINAVICA, 1990, 61 (01) :26-28
[5]
Gradisar I A Jr, 1989, J Arthroplasty, V4, P27, DOI 10.1016/S0883-5403(89)80050-6
[6]
*ISO CD, 1997, 148791 ISOCD BRIT ST
[7]
MASON MD, 1994, ORTHOP P, V17, P1091
[8]
MENDES DG, 1984, ORTHOPEDICS, V7, P860, DOI 10.3928/0147-7447-19840501-12
[9]
MORELAND JR, 1988, CLIN ORTHOP RELAT R, P49
[10]
MORREY BF, 1988, CLIN ORTHOP RELAT R, P182