Accuracy of joint aspiration for the preoperative diagnosis of infection in total hip arthroplasty

被引:130
作者
Ali, F
Wilkinson, JM
Cooper, JR
Kerry, RM
Hamer, AJ
Norman, P
Stockley, I
机构
[1] No Gen Hosp, Lower Limb Arthroplasty Unit, Sheffield S5 7AU, S Yorkshire, England
[2] No Gen Hosp, Dept Radiol, Sheffield S5 7AU, S Yorkshire, England
[3] No Gen Hosp, Dept Microbiol, Sheffield S5 7AU, S Yorkshire, England
关键词
aspiration; total hip arthroplasty; infection; diagnosis;
D O I
10.1016/j.arth.2005.05.027
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of this study was to assess the diagnostic accuracy of radiology department-based hip aspiration for the diagnosis of infection after total hip arthroplasty. Patient selection criteria were devised so that only patients with moderate to high risk of infection were selected for hip aspiration. Seventy-three patients are included in this study, all of whom underwent revision hip surgery after aspiration. Culture results of hip aspirates were compared with the intraoperative tissue cultures at the time of revision surgery, which was used as the gold standard for diagnosing infection. Seventeen patients (23%) had infected hip joints at operative culture. The sensitivity and specificity, positive and negative predictive values, and accuracy of the hip aspiration were 0.82 and 0.91, 0.74 and 0.94, and 0.89, respectively. We conclude that hip aspiration carried out in the radiology department is reliable, but appropriate patient selection is important to obtain accurate results.
引用
收藏
页码:221 / 226
页数:6
相关论文
共 19 条
[1]   Prospective evaluation of criteria for microbiological diagnosis of prosthetic-joint infection at revision arthroplasty [J].
Atkins, BL ;
Athanasou, N ;
Deeks, JJ ;
Crook, DWM ;
Simpson, H ;
Peto, TEA ;
McLardy-Smith, P ;
Berendt, AR .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (10) :2932-2939
[2]   THE VALUE OF ASPIRATION OF THE HIP-JOINT BEFORE REVISION TOTAL HIP-ARTHROPLASTY [J].
BARRACK, RL ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (01) :66-76
[3]  
Blake M P, 1995, Australas Radiol, V39, P10, DOI 10.1111/j.1440-1673.1995.tb00223.x
[4]   Aspiration as a guide to sepsis in revision total hip arthroplasty [J].
Fehring, TK ;
Cohen, B .
JOURNAL OF ARTHROPLASTY, 1996, 11 (05) :543-547
[5]   DEEP WOUND SEPSIS FOLLOWING TOTAL HIP ARTHROPLASTY [J].
FITZGERALD, RH ;
NOLAN, DR ;
ILSTRUP, DM ;
VANSCOY, RE ;
WASHINGTON, JA ;
COVENTRY, MB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) :847-855
[6]  
GARDENER MJ, 1992, CONFIDENCE INTERVAL
[7]   CURRENT CONCEPTS REVIEW INFECTION AFTER TOTAL HIP-ARTHROPLASTY PAST, PRESENT, AND FUTURE [J].
GARVIN, KL ;
HANSSEN, AD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (10) :1576-1588
[8]  
GOULD ES, 1990, SKELETAL RADIOL, V19, P427
[9]  
KAMME C, 1981, CLIN ORTHOP RELAT R, P201
[10]   Aspiration of the hip joint before revision total hip arthroplasty - Clinical and laboratory factors influencing attainment of a positive culture [J].
Lachiewicz, PF ;
Rogers, GD ;
Thomason, HC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (05) :749-754