Repeatability of maximal voluntary force and of surface EMG variables during voluntary isometric contraction of quadriceps muscles in healthy subjects

被引:108
作者
Rainoldi, A
Bullock-Saxton, JE
Cavarretta, F
Hogan, N
机构
[1] Politecn Torino, Dipartimento Elettron, Ctr Bioingegneria, I-10129 Turin, Italy
[2] Univ Roma Tor Vergata, Dept Phys Med & Rehabil, Rome, Italy
[3] Fondaz Don Gnocchi, Rome, Italy
[4] Univ Queensland, Sch Hlth & Rehabil Sci, Dept Physiotherapy, Brisbane, Qld, Australia
关键词
isometric contraction; torque measurement; vastus lateralis; vastus medialis obliquus surface electromyography; fatigue; repeatability; conduction velocity; spectral frequency; amplitude variables; ANOVA; ICC;
D O I
10.1016/S1050-6411(01)00022-0
中图分类号
Q189 [神经科学];
学科分类号
071006 [神经生物学];
摘要
The repeatability of initial values and rate of change of EMG signal mean spectral frequency (MNF), average rectified values (ARV), muscle fiber conduction velocity (CV) and maximal voluntary contraction (MVC) was investigated in the vastus medialis obliquus (VMO) and vastus lateralis (VL) muscles of both legs of nine healthy male subjects during voluntary, isometric contractions sustained for 50 s at 50% MVC. The values of MVC were recorded for both legs three times on each day and for three subsequent days, while the EMG signals have been recorded twice a day for three subsequent days. The degree of repeatability was investigated using the Fisher test based upon the ANalysis Of VAriance (ANOVA), the Standard Error of the Mean (SEM) and the Intraclass Correlation Coefficient (ICC). Data collected showed a high level of repeatability of MVC measurement (normalized SEM from 1.1% to 6.4% of the mean). MNF and ARV initial values also showed a high level of repeatability (ICC > 70% for all muscles and legs except right VMO). At 50% MVC level no relevant pattern of fatigue was observed for the VMO and VL muscles, suggesting that other portions of the quadriceps might have contributed to the generated effort. These observations seem to suggest that in the investigation of muscles belonging to a multi-muscular group at submaximal level, the more selective electrically elicited contractions should be preferred to voluntary contractions. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:425 / 438
页数:14
相关论文
共 40 条
[1]
MOTOR UNIT RECRUITMENT STRATEGY OF KNEE ANTAGONIST MUSCLES IN A STEP-WISE, INCREASING ISOMETRIC CONTRACTION [J].
BERNARDI, M ;
SOLOMONOW, M ;
SANCHEZ, JH ;
BARATTA, RV ;
NGUYEN, G .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1995, 70 (06) :493-501
[2]
BIEDERMANN H J, 1990, Electromyography and Clinical Neurophysiology, V30, P83
[3]
BIEDERMANN HJ, 1991, J ELECTROMYOGR KINES, V1, P228
[4]
EMG POWER SPECTRA OF ELBOW EXTENSORS DURING RAMP AND STEP ISOMETRIC CONTRACTIONS [J].
BILODEAU, M ;
ARSENAULT, AB ;
GRAVEL, D ;
BOURBONNAIS, D .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1991, 63 (01) :24-28
[5]
Bilodeau M, 1994, Electromyogr Clin Neurophysiol, V34, P149
[6]
BUSKIRK E, 1970, ELECTROMYOGRAPHY, V10, P357
[7]
Electromyogram amplitude estimation with adaptive smoothing window length [J].
Clancy, EA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (06) :717-729
[8]
REPRODUCIBILITY OF THE MEAN POWER FREQUENCY OF THE SURFACE ELECTROMYOGRAM [J].
DAANEN, HAM ;
MAZURE, M ;
HOLEWIJN, M ;
VANDERVELDE, EA .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1990, 61 (3-4) :274-277
[9]
USE OF THE SURFACE EMG SIGNAL FOR PERFORMANCE EVALUATION OF BACK MUSCLES [J].
DE LUCA, CJ .
MUSCLE & NERVE, 1993, 16 (02) :210-216
[10]
The use of surface electromyography in biomechanics [J].
De Luca, CJ .
JOURNAL OF APPLIED BIOMECHANICS, 1997, 13 (02) :135-163