Spatial mapping of the percentage cellularity in human bone marrow using magnetic resonance imaging

被引:14
作者
Ballon, D
Jakubowski, AA
Graham, MC
Schneider, E
Koutcher, JA
机构
[1] MEM SLOAN KETTERING CANC CTR,DEPT MED PHYS,NEW YORK,NY 10021
[2] MEM SLOAN KETTERING CANC CTR,DEPT RADIOL,NEW YORK,NY 10021
[3] MEM SLOAN KETTERING CANC CTR,DEPT MED,NEW YORK,NY 10021
[4] GE CO,CORP RES & DEV,ELECTR SYST LAB,SCHENECTADY,NY 12301
关键词
bone marrow; chemical shift imaging; cellularity;
D O I
10.1118/1.597796
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A noninvasive assay for the spatial distribution of the percentage cellularity in human bone marrow is presented. Twelve individuals were studied using two magnetic resonance imaging techniques: (1) fast spin echo imaging with frequency selective presaturation, and (2) three-point chemical shift imaging. The data were compared to results obtained using a previously validated stimulated echo spectroscopic method. The results of this study demonstrate that a measure of the percentage cellularity in bone marrow is possible using magnetic resonance imaging techniques provided that high-quality water or lipid suppression is achieved across the region of interest. Since the method is applicable to bone marrow at any anatomic location, it may prove useful in dosimetric calculations during and after a course of internal or external beam radiotherapy. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:243 / 250
页数:8
相关论文
共 16 条
  • [1] INVIVO MEASUREMENTS OF BONE-MARROW CELLULARITY USING VOLUME-LOCALIZED PROTON NMR-SPECTROSCOPY
    BALLON, D
    JAKUBOWSKI, A
    GABRILOVE, J
    GRAHAM, MC
    ZAKOWSKI, M
    SHERIDAN, C
    KOUTCHER, JA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (01) : 85 - 95
  • [2] MR-IMAGING OF FAT-CONTAINING TISSUES - VALUATION OF 2 QUANTITATIVE IMAGING TECHNIQUES IN COMPARISON WITH LOCALIZED PROTON SPECTROSCOPY
    BRIX, G
    HEILAND, S
    BELLEMANN, ME
    KOCH, T
    LORENZ, WJ
    [J]. MAGNETIC RESONANCE IMAGING, 1993, 11 (07) : 977 - 991
  • [3] QUANTITATIVE PROTON CHEMICAL-SHIFT IMAGING
    BUXTON, RB
    WISMER, GL
    BRADY, TJ
    ROSEN, BR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) : 881 - 900
  • [4] SIMPLE PROTON SPECTROSCOPIC IMAGING
    DIXON, WT
    [J]. RADIOLOGY, 1984, 153 (01) : 189 - 194
  • [5] STIMULATED ECHO IMAGING
    FRAHM, J
    MERBOLDT, KD
    HANICKE, W
    HAASE, A
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (01) : 81 - 93
  • [6] MULTIPOINT DIXON TECHNIQUE FOR WATER AND FAT PROTON AND SUSCEPTIBILITY IMAGING
    GLOVER, GH
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (05): : 521 - 530
  • [7] 3-POINT DIXON TECHNIQUE FOR TRUE WATER FAT DECOMPOSITION WITH BO INHOMOGENEITY CORRECTION
    GLOVER, GH
    SCHNEIDER, E
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) : 371 - 383
  • [8] GRAHAM MC, 1994, AM ASS PHYSICISTS ME
  • [9] H-1-NMR CHEMICAL-SHIFT SELECTIVE (CHESS) IMAGING
    HAASE, A
    FRAHM, J
    HANICKE, W
    MATTHAEI, D
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (04) : 341 - 344
  • [10] SPIN ECHOES
    HAHN, EL