Comparison of two different pulse oximeters in monitoring preterm infants

被引:9
作者
Grieve, SH
McIntosh, N
Laing, IA
机构
[1] NEONATOL UNIT,EDINBURGH EH3 9YW,MIDLOTHIAN,SCOTLAND
[2] UNIV EDINBURGH,DEPT CHILD LIFE & HLTH,EDINBURGH,MIDLOTHIAN,SCOTLAND
基金
英国惠康基金;
关键词
pulse oximetry; transcutaneous oxygen monitoring; bedside computer monitoring; neonatal; preterm infants; monitoring of;
D O I
10.1097/00003246-199712000-00025
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: The aim of the study was to test the reliability and Variation in the readings of two widely used pulse oximeters in preterm infants. Design: Two different pulse oximeters and a transcutaneous PO2 monitor were used to record the data continuously on a cotside computer database. Patients: Sixteen preterm infants were studied in the Neonatal Unit, Simpson Memorial Maternity Pavilion, Edinburgh, UK, Interventions: None. Measurements and Main Results: Approximately one fifth of the time, the pulse oximeter readings could be established as artifactual. Study of the remaining four fifths of the data showed that, on average, the Nellcor pulse oximeter recorded saturation percentages 2.2% higher than the Ohmeda oximeter. Conclusions: We recommend that all neonatal units adopt a policy of using different saturation alarm limits for these two instruments. We further recommend that other pulse oximeters be tested by a methodology similar to the one we present in this paper, before their use in monitoring oxygenation in preterm infants.
引用
收藏
页码:2051 / 2054
页数:4
相关论文
共 13 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
BUCHER HU, 1989, PEDIATRICS, V84, P226
[3]   TRANS-CUTANEOUS MONITORING IN THE NEWBORN-INFANT [J].
CASSADY, G .
JOURNAL OF PEDIATRICS, 1983, 103 (06) :837-848
[4]   DIFFERENTIAL-EFFECTS OF OXYGEN AND BAROTRAUMA ON LUNG INJURY IN THE NEONATAL PIGLET [J].
DAVIS, JM ;
DICKERSON, B ;
METLAY, L ;
PENNEY, DP .
PEDIATRIC PULMONOLOGY, 1991, 10 (03) :157-163
[5]   PULSE OXIMETRY IN NEONATAL MEDICINE [J].
HAY, WW ;
THILO, E ;
CURLANDER, JB .
CLINICS IN PERINATOLOGY, 1991, 18 (03) :441-472
[6]  
HAY WW, 1989, PEDIATRICS, V83, P717
[7]  
HODSON WA, 1994, NEONATOLOGY PATHOPHY, P478
[8]  
LAING IA, 1993, BR J INTENSIVE CARE, P16
[9]   Uses and abuses of pulse oximetry [J].
Moyle, JTB .
ARCHIVES OF DISEASE IN CHILDHOOD, 1996, 74 (01) :77-80
[10]   STUDIES ON THE EFFECT OF HIGH OXYGEN ADMINISTRATION IN RETROLENTAL FIBROPLASIA .1. NURSERY OBSERVATIONS [J].
PATZ, A ;
HOECK, LE ;
DELACRUZ, E .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1952, 35 (09) :1248-1253