Practical recommendations for managing hemolyzed samples in clinical chemistry testing

被引:98
作者
Lippi, Giuseppe [1 ]
Cadamuro, Janne [2 ]
von Meyer, Alexander [3 ,4 ,5 ,6 ]
Simundic, Ana-Maria [7 ]
机构
[1] Univ Hosp Verona, Sect Clin Biochem, Piazzale LA Scuro, I-37100 Verona, Italy
[2] Paracelsus Med Univ, Dept Lab Med, Salzburg, Austria
[3] Kliniken Nordoberpfalz AG, Inst Lab Med, Weiden, Germany
[4] Klinikum St Marien, Weiden, Germany
[5] Kliniken Nordoberpfalz AG, Inst Lab Med, Amberg, Germany
[6] Klinikum St Marien, Amberg, Germany
[7] Univ Hosp Sveti Duh, Dept Med Lab Diagnost, Zagreb, Croatia
关键词
hemolysis; interference; quality; safety; REFERENCE CHANGE VALUES; IN-VITRO HEMOLYSIS; BIOLOGICAL VARIATION; EUROPEAN FEDERATION; LABORATORY MEDICINE; PREANALYTICAL PHASE; VISUAL ASSESSMENT; WORKING GROUP; INTERFERENCE; SPECIMENS;
D O I
10.1515/cclm-2017-1104
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
We suggest here a pragmatic approach for managing results of clinical chemistry testing in hemolyzed samples collected from adults/older children, attempting to balance the need to produce quality laboratory data with clinical urgency of releasing test results. Automatic measurement of the hemolysis index (H-index) in serum or plasma is highly advisable, whilst low-quality assessment of this test remains less good than a visual inspection. Regarding its practical use, when the H-index value does not generate an analytically significant bias, results can be released, whilst when the value is associated with analyte variation in a range between analytically and clinically significant bias (i.e. variation does not exceed the reference change value [RCV]), results of hemolysis-sensitive tests can be released in association with a comment describing the direction in which data are potentially altered, suggesting the need to collect another sample. When the H-index is associated with analyte variation exceeding clinically significant bias (i.e. variation exceeds the RCV), results of hemolysis-sensitive tests should be suppressed and replaced with a comment that biased results cannot be released because the sample is preanalytically compromised and advising the recollection of another sample. If H-index values reach an even higher critical cut-off (i.e. H-index corresponding to a cell-free hemoglobin concentration >= 10 g/L), all laboratory data may be unreliable and should hence be suppressed and replaced with a comment that all data cannot be released because the sample is grossly hemolyzed, also suggesting the recollection of another sample. Due to inaccuracy and imprecision, the use of corrective formulas for adjusting data of hemolysis-sensitive tests is discouraged.
引用
收藏
页码:718 / 727
页数:10
相关论文
共 60 条
[1]  
[Anonymous], TFG BVD BIOL VAL DAT
[2]  
[Anonymous], IN VITRO VIVO HEMOLY
[3]   Verification of examination procedures in clinical laboratory for imprecision, trueness and diagnostic accuracy according to ISO 15189:2012: a pragmatic approach [J].
Antonelli, Giorgia ;
Padoan, Andrea ;
Aita, Ada ;
Sciacovelli, Laura ;
Plebani, Mario .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (10) :1501-1508
[4]  
Badrick Tony, 2016, Clin Biochem Rev, V37, P140
[5]   A checklist for critical appraisal of studies of biological variation [J].
Bartlett, William A. ;
Braga, Federica ;
Carobene, Anna ;
Coskun, Abdurrahman ;
Prusa, Richard ;
Fernandez-Calle, Pilar ;
Roraas, Thomas ;
Jonker, Neils ;
Sandberg, Sverre .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2015, 53 (06) :879-885
[6]   To report or not to report: a proposal on how to deal with altered test results in hemolytic samples [J].
Cadamuro, Janne ;
Mrazek, Cornelia ;
Haschke-Becher, Elisabeth ;
Sandberg, Sverre .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (08) :1109-1111
[7]   A pragmatic approach to sample acceptance and rejection [J].
Cadamuro, Janne ;
Simundic, Ana-Maria ;
Ajzner, Eva ;
Sandberg, Sverre .
CLINICAL BIOCHEMISTRY, 2017, 50 (10-11) :579-581
[8]   Hemolysis rates in blood samples: differences between blood collected by clinicians and nurses and the effect of phlebotomy training [J].
Cadamuro, Janne ;
von Meyer, Alexander ;
Wiedemann, Helmut ;
Felder, Thomas Klaus ;
Moser, Franziska ;
Kipman, Ulrike ;
Haschke-Becher, Elisabeth ;
Mrazek, Cornelia ;
Simundic, Ana-Maria .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (12) :1987-1992
[9]  
Cadamuro J, 2016, LABORATORIUMSMEDIZIN, V40, P49, DOI 10.1515/labmed-2015-0078
[10]   The EuBIVAS Project: Within- and Between-Subject Biological Variation Data for Serum Creatinine Using Enzymatic and Alkaline Picrate Methods and Implications for Monitoring [J].
Carobene, Anna ;
Marino, Irene ;
Coskun, Abdurrahman ;
Serteser, Mustafa ;
Unsal, Ibrahim ;
Guerra, Elena ;
Bartlett, William A. ;
Sandberg, Sverre ;
Aarsand, Aasne Karine ;
Sylte, Marit Sverresdotter ;
Roraas, Thomas ;
Solvik, Una Orvim ;
Fernandez-Calle, Pilar ;
Diaz-Garzon, Jorge ;
Tosato, Francesca ;
Plebani, Mario ;
Jonker, Niels ;
Barla, Gerhard ;
Ceriotti, Ferruccio .
CLINICAL CHEMISTRY, 2017, 63 (09) :1527-1536