Does epinephrine improve the diagnostic accuracy of aspiration during labor epidural analgesia?

被引:41
作者
Norris, MC [1 ]
Ferrenbach, D [1 ]
Dalman, H [1 ]
Fogel, ST [1 ]
Borrenpohl, S [1 ]
Hoppe, W [1 ]
Riley, A [1 ]
机构
[1] Washington Univ, Sch Med, Dept Anesthesiol, St Louis, MO 63110 USA
关键词
D O I
10.1097/00000539-199905000-00019
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Aspiration reliably detects almost all IV multiorifice epidural catheters. Although a supplemental epinephrine 15-mu g test dose may detect the rare TV catheter that does not yield blood on aspiration, false-positive epinephrine responses may cause some women to unnecessarily undergo repeat epidural catheter insertion. We evaluated 532 consecutive eligible patients requesting neuraxial labor analgesia. Patients were excluded if they had a contraindication to epinephrine or if they received intrathecal sufentanil/bupivacaine. Multiorifice catheters were inserted 4-6 cm into the epidural space as part of an epidural (n = 305) or combined spinal-epidural (n = 270) technique. We used aspiration, a lidocaine/epinephrine test dose, and bolus injection or infusion of dilute bupivacaine/sufentanil solutions to systematically determine TV, intrathecal, or epidural catheter location. Aspiration alone detected 47 of 48 intravascular catheters. There were 10 positive epinephrine responses: 2 were true positives, 7 were falsely positive (subsequent local anesthetic injection/infusion produced bilateral sensory change and analgesia), and 1 catheter was removed without further testing. Aspiration detected almost all intravascular catheters. Although the epinephrine test dose did detect one catheter that proved to be in a blood vessel, 87.5% of positive responses occurred in women without intravascular catheters. Implications: Epidural catheters may enter a blood vessel. Many clinicians use epinephrine to detect these catheters. Because aspiration alone detects almost all TV multiorifice catheters in laboring women, a subsequent epinephrine test dose may be unnecessary.
引用
收藏
页码:1073 / 1076
页数:4
相关论文
共 13 条
[1]   EPINEPHRINE SHOULD BE USED WITH THE THERAPEUTIC DOSE OF BUPIVACAINE IN OBSTETRICS [J].
ALBRIGHT, GA .
ANESTHESIOLOGY, 1984, 61 (02) :217-218
[2]   CARDIAC-ARREST FOLLOWING REGIONAL ANESTHESIA WITH ETIDOCAINE OR BUPIVACAINE [J].
ALBRIGHT, GA .
ANESTHESIOLOGY, 1979, 51 (04) :285-287
[3]   EPIDURAL CATHETERS OF THE MULTI-ORIFICE TYPE - DANGERS AND COMPLICATIONS [J].
BECK, H ;
BRASSOW, F ;
DOEHN, M ;
BAUSE, H ;
DZIADZKA, A ;
ESCH, JSA .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1986, 30 (07) :549-555
[4]   MATERNAL HEART-RATE CHANGES WITH A PLAIN EPIDURAL TEST DOSE [J].
CARTWRIGHT, PD ;
MCCARROLL, SM ;
ANTZAKA, C .
ANESTHESIOLOGY, 1986, 65 (02) :226-228
[5]  
Colonna-Romano P, 1998, ANESTH ANALG, V86, P985
[6]  
KENEPP NB, 1981, ANESTHESIOLOGY, V54, P172
[7]   LIMITATIONS OF EPINEPHRINE AS A MARKER OF INTRAVASCULAR INJECTION IN LABORING WOMEN [J].
LEIGHTON, BL ;
NORRIS, MC ;
SOSIS, M ;
EPSTEIN, R ;
CHAYEN, B ;
LARIJANI, GE .
ANESTHESIOLOGY, 1987, 66 (05) :688-691
[8]   THE AIR TEST AS A CLINICALLY USEFUL INDICATOR OF INTRAVENOUSLY PLACED EPIDURAL CATHETERS [J].
LEIGHTON, BL ;
NORRIS, MC ;
DESIMONE, CA ;
ROSKO, T ;
GROSS, JB .
ANESTHESIOLOGY, 1990, 73 (04) :610-613
[9]   THE COMPONENTS OF AN EFFECTIVE TEST DOSE PRIOR TO EPIDURAL BLOCK [J].
MOORE, DC ;
BATRA, MS .
ANESTHESIOLOGY, 1981, 55 (06) :693-696
[10]   Safety steps for epidural injection of local anesthetics: Review of the literature and recommendations [J].
Mulroy, MF ;
Norris, MC ;
Liu, SS .
ANESTHESIA AND ANALGESIA, 1997, 85 (06) :1346-1356