What technical barriers exist for real-time fluoroscopic and video image overlay in robotic surgery?

被引:2
作者
Afthinos, J. N. [2 ]
Latif, M. J. [2 ]
Bhora, F. Y. [3 ]
Connery, C. P. [3 ]
McGinty, J. J. [2 ]
Burra, A. [1 ]
Attiyeh, M. [2 ]
Todd, G. J. [2 ]
Belsley, S. J. [1 ]
机构
[1] Columbia Univ Coll Phys & Surg, St Lukes Roosevelt Hosp Ctr, Div Robot Surg, New York, NY 10019 USA
[2] Columbia Univ Coll Phys & Surg, St Lukes Roosevelt Hosp Ctr, Dept Surg, New York, NY 10019 USA
[3] Columbia Univ Coll Phys & Surg, St Lukes Roosevelt Hosp Ctr, Div Thorac Surg, New York, NY 10019 USA
关键词
image overlay; robotic surgery; surgical navigation; fluoroscopy; minimally invasive surgery;
D O I
10.1002/rcs.221
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background A hypothetical advantage of the da Vinci (R) console is its ability to integrate multiple visual data sources. Current platforms for augmented reality surgery fuse pre-operative radiographic studies but are limited with their ability to update with intra-operative imaging. The aim of our study was to evaluate the feasibility of real-time radiographic image overlay with current technology. Methods S-video composite output from a fluoroscopic C-arm was superimposed onto the video output of the da Vinci device. Image superimposition disparity measurements were evaluated in a bench model. The feasibility of robotic dissection assisted by real-time cholangiogram and intravenous pyelogram was evaluated. Results Image alignment resulted in a radiographic blind spot and image disparity with severely limited application in an in vivo model. Conclusions External collisions of the robotic device and visual disparity in multiple planes negate the current implementation of fluoroscopic overlay and will require more elegant methods of computer-assisted registration. Copyright (C) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:368 / 372
页数:5
相关论文
共 21 条
[1]   An Image Overlay system for medical data visualization [J].
Blackwell, M ;
Nikou, C ;
DiGioia, AM ;
Kanade, T .
MEDICAL IMAGE ANALYSIS, 2000, 4 (01) :67-72
[2]  
Deutschmann H, 2008, STRAHLENTHER ONKOL, V184, P93, DOI 10.1007/s00066-008-1742-5
[3]   Cardio navigation:: Planning, simulation, and augmented reality in robotic assisted endoscopic bypass grafting [J].
Falk, V ;
Mourgues, F ;
Adhami, L ;
Jacobs, S ;
Thiele, H ;
Nitzsche, S ;
Mohr, FW ;
Coste-Manière, T .
ANNALS OF THORACIC SURGERY, 2005, 79 (06) :2040-2048
[4]  
Falk Volkmar, 2005, Surg Technol Int, V14, P231
[5]   An interactive medical image segmentation system based on the optimal management of regions of interest using topological medical knowledge [J].
Fasquel, Jean-Baptiste ;
Agnus, Vincent ;
Moreau, Johan ;
Soler, Luc ;
Marescaux, Jacques .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2006, 82 (03) :216-230
[6]   Endoscopic augmented reality navigation system for endonasal transsphenoidal surgery to treat pituitary tumors: Technical note [J].
Kawamata, T ;
Iseki, H ;
Shibasaki, T ;
Hori, T .
NEUROSURGERY, 2002, 50 (06) :1393-1397
[7]   Large or small bore, push or pull: A comparison of three classes of percutaneous fluoroscopic gastrostomy catheters [J].
Kuo, Yuo-Chen ;
Shlansky-Goldberg, Richard D. ;
Mondschein, Jeffrey I. ;
Stavropoulos, S. William ;
Patel, Aalpen A. ;
Solomon, Jeffrey A. ;
Soulen, Michael C. ;
Kwak, Andrew ;
Itkin, Maxim ;
Chittams, Jesse L. ;
Trerotola, Scott O. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (04) :557-564
[8]   Surgical navigation by auto stereo scopic image overlay of integral videography [J].
Liao, H ;
Hata, N ;
Nakajima, S ;
Iwahara, M ;
Sakuma, I ;
Dohi, T .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2004, 8 (02) :114-121
[9]   Augmented-reality-assisted laparoscopic adrenalectomy [J].
Marescaux, J ;
Rubino, F ;
Arenas, M ;
Mutter, D ;
Soler, L .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 292 (18) :2214-2215
[10]   Endovascular stent-graft repair of thoracic aortic aneurysms [J].
Mitchell, RS ;
Dake, MD ;
Semba, CP ;
Fogarty, TJ ;
Zarins, CK ;
Liddell, RP ;
Miller, DC .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (05) :1054-1060