Comparison of stenting and balloon angioplasty for narrowings in aortocoronary saphenous vein conduits in place for more than five years

被引:40
作者
Brener, SJ
Ellis, SG
AppersonHansen, C
Leon, MB
Topol, EJ
机构
[1] CLEVELAND CLIN FDN,DEPT CARDIOL,CLEVELAND,OH 44195
[2] WASHINGTON HOSP CTR,DEPT INTERNAL MED,WASHINGTON,DC 20010
关键词
D O I
10.1016/S0002-9149(96)00668-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To compare the 1 year outcome of Palmaz-Schatz stent implantation versus balloon angioplasty for treatment of obstructive lesions in saphenous vein grafts, we combined databases from the Palmaz-Schatz vein graft stent registry and the coronary angioplasty arm of the Coronary Angioplasty Versus Excisional Atherectomy Trial II (CAVEAT II) for comparison of baseline characteristics, procedural variables, in-hospital events and 1-year composite end point of death, Q-wave myocardial infarction, and repeat target vessel revascularization. De novo graft lesions not involving the ostia were treated with stent implantation in 377 patients and with coronary angioplasty in 156 patients. The patients were comparable in age, coronary risk profile, interval from bypass surgery (9 +/- 4 years), and reference vessel diameter. The in-hospital composite end point of death, myocardial infarction, and emergency revascularization was lower in the stent group (10%) than in the angioplasty cohort (17%) (p = 0.059). At 1 year, the patients in the stent group had a markedly lower incidence of the composite end point of death, myocardial infarction, or revascularization (23% vs 45%, p < 0.001). In this nonrandomized comparison with balloon angioplasty, the treatment of lesions in saphenous vein grafts appears to be favorably influenced by Palmaz-Schatz stent implantation, in terms of in-hospital events and clinical restenosis at 1 year follow-up. (C) 1997 by Excerpta Medica, Inc.
引用
收藏
页码:13 / 18
页数:6
相关论文
共 24 条
  • [1] PROGRESSION OF ATHEROSCLEROSIS IN CORONARY-ARTERIES AND BYPASS GRAFTS - 10 YEARS LATER
    BOURASSA, MG
    ENJALBERT, M
    CAMPEAU, L
    LESPERANCE, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (12) : C102 - C107
  • [2] INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE
    COLOMBO, A
    HALL, P
    NAKAMURA, S
    ALMAGOR, Y
    MAIELLO, L
    MARTINI, G
    GAGLIONE, A
    GOLDBERG, SL
    TOBIS, JM
    [J]. CIRCULATION, 1995, 91 (06) : 1676 - 1688
  • [3] PERCUTANEOUS TRANS-LUMINAL ANGIOPLASTY OF STENOTIC CORONARY-ARTERY BYPASS GRAFTS - 5 YEARS EXPERIENCE
    COTE, G
    MYLER, RK
    STERTZER, SH
    CLARK, DA
    FISHMANROSEN, J
    MURPHY, M
    SHAW, RE
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (01) : 8 - 17
  • [4] BALLOON ANGIOPLASTY FOR THE TREATMENT OF LESIONS IN SAPHENOUS-VEIN BYPASS GRAFTS
    DEFEYTER, PIMJ
    VANSUYLEN, RJ
    DEJAEGERE, PPT
    TOPOL, EJ
    SERRUYS, PW
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (07) : 1539 - 1549
  • [5] DOUGLAS JS, 1994, TXB INTERVENTIONAL C, P339
  • [6] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [7] CORONARY-BYPASS GRAFT FATE - LONG-TERM ANGIOGRAPHIC STUDY
    FITZGIBBON, GM
    LEACH, AJ
    KAFKA, HP
    KEON, WJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (05) : 1075 - 1080
  • [8] RESTENOSIS AFTER DIRECTIONAL CORONARY ATHERECTOMY
    HINOHARA, T
    ROBERTSON, GC
    SELMON, MR
    VETTER, JW
    ROWE, MH
    BRADEN, LJ
    MCAULEY, BJ
    SHEEHAN, DJ
    SIMPSON, JB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (03) : 623 - 632
  • [9] RESTENOSIS AFTER CORONARY ANGIOPLASTY - A MULTIVARIATE STATISTICAL-MODEL TO RELATE LESION AND PROCEDURE VARIABLES TO RESTENOSIS
    HIRSHFELD, JW
    SCHWARTZ, JS
    JUGO, R
    MACDONALD, RG
    GOLDBERG, S
    SAVAGE, MP
    BASS, TA
    VETROVEC, G
    COWLEY, M
    TAUSSIG, AS
    WHITWORTH, HB
    MARGOLIS, JR
    HILL, JA
    PEPINE, CJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (03) : 647 - 656
  • [10] A MULTICENTER, RANDOMIZED TRIAL OF CORONARY ANGIOPLASTY VERSUS DIRECTIONAL ATHERECTOMY FOR PATIENTS WITH SAPHENOUS-VEIN BYPASS GRAFT LESIONS
    HOLMES, DR
    TOPOL, EJ
    CALIFF, RM
    BERDAN, LG
    LEYA, F
    BERGER, PB
    WHITLOW, PL
    SAFIAN, RD
    ADELMAN, AG
    KELLETT, MA
    TALLEY, JD
    SHANI, J
    GOTTLIEB, RS
    PINKERTON, CA
    LEE, KL
    KEELER, GP
    ELLIS, SG
    FRANCO, I
    DEBOWEY, D
    LINCOFF, M
    KEREIAKES, D
    ABBOTTSMITH, C
    KENT, K
    LEON, M
    PICHARD, A
    SATLER, L
    POPMA, J
    HINOHARA, T
    KOSINSKI, E
    SIMONTON, C
    BERSIN, RM
    CEDARHOLM, J
    WILSON, B
    MCKEEVER, LS
    MARTIN, F
    CHAPEKIS, A
    GEORGE, BS
    COWLEY, M
    PINKERTON, C
    PETERS, T
    COHEN, M
    JACOBS, A
    FAXON, DP
    LEVINE, G
    KELLETT, M
    KING, S
    MASDEN, R
    MOONEY, M
    WHITE, CJ
    HOFLING, B
    [J]. CIRCULATION, 1995, 91 (07) : 1966 - 1974