Evaluation of capillary electrophoretic techniques towards systematic toxicological analysis

被引:23
作者
Boone, CM [1 ]
Franke, JP [1 ]
de Zeeuw, RA [1 ]
Ensing, K [1 ]
机构
[1] Univ Groningen, Ctr Pharm, Dept Analyt Chem & Toxicol, NL-9713 AV Groningen, Netherlands
关键词
toxicological analysis; identification power; barbiturates;
D O I
10.1016/S0021-9673(99)00085-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Two capillary electrophoresis (CE) methods were evaluated for their suitability in systematic toxicological analysis (STA). A test set of 25 barbiturates was analysed using capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC). Buffers used consisted of 90 mM berate set at pH 8.4 (CZE) and 20 mM phosphate, 50 mM sodium dodecyl sulphate set at pH 7.5 (MEKC). All analyses were carried out using fused silica capillaries using an electric field strength of 52.6 kV/m. The use of a reproducible identification parameter is very important in STA as it influences the identification power (IP). To deal with the poor reproducibility of the migration time, we introduced the corrected effective mobility. Inter-day reproducibilities of the latter parameter were <0.6% for CZE and <0.5% for MEKC, using daily prepared buffers. The IP of the methods was expressed by calculation of the discriminating power and the mean list length. Data obtained were compared to gas chromatographic and high-performance liquid chromatographic data, and correlations between all methods were calculated. It was shown that little correlation exists between chromatographic and electrophoretic techniques. The results indicated that CE has a good identification power for the application in STA, especially when a combination of methods having a low correlation is used. (C) 1999 Elsevier Science BN. All rights reserved.
引用
收藏
页码:259 / 272
页数:14
相关论文
共 28 条
[1]  
[Anonymous], 1998, J CAN SOC FORENSIC S
[2]   DETERMINATION OF ABSOLUTE MOBILITIES, PK VALUES AND SEPARATION NUMBERS BY CAPILLARY ZONE ELECTROPHORESIS - EFFECTIVE MOBILITY AS A PARAMETER FOR SCREENING [J].
BECKERS, JL ;
EVERAERTS, FM ;
ACKERMANS, MT .
JOURNAL OF CHROMATOGRAPHY, 1991, 537 (1-2) :407-428
[3]   Drug screening in biological fluids - The need for a systematic approach [J].
deZeeuw, RA .
JOURNAL OF CHROMATOGRAPHY B, 1997, 689 (01) :71-79
[4]  
DEZEEUW RA, 1994, J CHROMATOGR A, V674, P3, DOI 10.1016/0021-9673(94)85214-6
[5]  
DHONT J, 1970, J CHROMATOGR, V46, P376
[6]   APPLICATION OF RF CORRECTION IN THIN-LAYER CHROMATOGRAPHY BY MEANS OF 2 REFERENCE RF-VALUES .2. RESULTS OBTAINED WITH A POLAR MULTI-COMPONENT SOLVENT SYSTEM [J].
DHONT, JH ;
DEZEEUW, RA ;
LABADIE, RP ;
VINKENBO.C ;
VERWEIJ, A ;
COMPAAN, H ;
RITTER, FJ .
JOURNAL OF CHROMATOGRAPHY, 1972, 71 (02) :283-&
[7]  
Doornbos D A, 1969, Pharm Weekbl, V104, P233
[8]  
FERSLEW KE, 1995, J FORENSIC SCI, V40, P245
[9]   AN OVERVIEW ON THE STANDARDIZATION OF CHROMATOGRAPHIC METHODS FOR SCREENING ANALYSIS IN TOXICOLOGY BY MEANS OF RETENTION INDEXES AND SECONDARY STANDARDS .1. GAS-CHROMATOGRAPHY [J].
FRANKE, JP ;
BOGUSZ, M ;
DEZEEUW, RA .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (3-4) :67-72
[10]  
FRANKE JP, 1990, J FORENSIC SCI, V35, P813