Ag@BSA Core/Shell Microspheres As an Electrochemical Interface for Sensitive Detection of Urinary Retinal-Binding Protein

被引:84
作者
Hu, Chenyi [2 ]
Yang, Da-Peng [1 ]
Xu, Kuan [2 ]
Cao, Hongmei [2 ]
Wu, Beina [2 ]
Cui, Daxiang [1 ]
Jia, Nengqin [2 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Micronanosci & Technol, Dept Bionanosci & Engn, Key Lab Thin Film & Microfabricat,Minist Educ, Shanghai 200240, Peoples R China
[2] Shanghai Normal Univ, Dept Chem, Life & Environm Sci Coll, Educ Minist,Key Lab Resource Chem, Shanghai 200234, Peoples R China
基金
中国国家自然科学基金;
关键词
CELL-SURFACE CARBOHYDRATE; ANTIGEN-ANTIBODY BINDING; IMPEDANCE SPECTROSCOPY; BIOSENSOR; ENZYME; ASSAY; SENSORS; NANOPARTICLES; IMMUNOSENSOR; TRANSFERRIN;
D O I
10.1021/ac3023795
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
The level of urinary retinol-binding protein (RBP) can be estimated as a significant index of renal tubular injury. In this work, we used Ag@BSA microspheres as a sensing interface to cross-link RBP monoclonal antibody (RBP rnAb) via glutaraldehyde for sensitive detection of RBP. The Ag@BSA microspheres covered on a Au electrode could provide a larger surface area and multifunctional substrate for the effective immobilization of RBP inAb, and the outside BSA layer acted as a biocompatible support to maintain the bioactivity and stability of immobilized immunogen. Electrochemical measurements containing electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV) were employed to evaluate the analytical performance of the fabricated immunosensor and a higher detection sensitivity was obtained by DPV attributed to the excellent electrical conductivity of Ag@BSA which could enhance the peak current response. This immunosensor had a best detection limit (DL) of 18 ng mL(-1) and a linear response range between 50 and 4500 ng mL(-1). The proposed approach showed high specificity for RBP detection, acceptable reproducibility with an RSD of 5.6%, and good precision with the RSD of 4.5% and 6.3% at the RBP concentrations of 500 and 1500 ng mL(-1). Compared with the ELISA method by analyzing real urine samples from a patient, this immunosensor revealed acceptable accuracy with a relative deviation lower than 6.5%, indicating a potential alternative method for RBP detection in clinical diagnosis.
引用
收藏
页码:10324 / 10331
页数:8
相关论文
共 42 条
[1]
The protein-nanomaterial interface [J].
Asuri, Prashanth ;
Bale, Shyam Sundhar ;
Karajanagi, Sandeep S. ;
Kane, Ravi S. .
CURRENT OPINION IN BIOTECHNOLOGY, 2006, 17 (06) :562-568
[2]
BEETHAM R, 1985, CLIN CHEM, V31, P1364
[3]
BERNARD AM, 1987, CLIN CHEM, V33, P775
[4]
BOWES J. H., 1966, J ROY MICROSCOP SOC, V85, P193
[5]
Noble-metal nanoparticles directly conjugated to globular proteins [J].
Burt, JL ;
Gutiérrez-Wing, C ;
Miki-Yoshida, M ;
José-Yacamán, M .
LANGMUIR, 2004, 20 (26) :11778-11783
[6]
Self-assembled monolayers as a tunable platform for biosensor applications [J].
Chaki, NK ;
Vijayamohanan, K .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (1-2) :1-12
[7]
AUTOMATED IMMUNOTURBIDIMETRIC METHODS FOR THE DETERMINATION OF RETINOL BINDING-PROTEIN, PREALBUMIN AND TRANSFERRIN IN URINE [J].
CHEUNG, CK ;
SWAMINATHAN, R .
CLINICAL BIOCHEMISTRY, 1989, 22 (06) :425-427
[8]
Metal-Salen Schiff base complexes in catalysis: practical aspects [J].
Cozzi, PG .
CHEMICAL SOCIETY REVIEWS, 2004, 33 (07) :410-421
[9]
Protein- and Peptide-Directed Syntheses of Inorganic Materials [J].
Dickerson, Matthew B. ;
Sandhage, Kenneth H. ;
Naik, Rajesh R. .
CHEMICAL REVIEWS, 2008, 108 (11) :4935-4978
[10]
Biofunctionalization of nanoparticles for cytosensing and cell surface carbohydrate assay [J].
Ding, Lin ;
Ju, Huangxian .
JOURNAL OF MATERIALS CHEMISTRY, 2011, 21 (45) :18154-18173