Strength assessment in postpolio syndrome: Validity of a hand-held dynamometer in detecting change

被引:26
作者
Nollet, F [1 ]
Beelen, A [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Rehabil Med, NL-1100 DD Amsterdam, Netherlands
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 1999年 / 80卷 / 10期
关键词
D O I
10.1016/S0003-9993(99)90036-9
中图分类号
R49 [康复医学];
学科分类号
100215 [康复医学与理疗学];
摘要
Objectives: To investigate the validity, the intraexaminer and interexaminer reproducibility, and the ability to detect change of a hand-held dynamometer (HHD) in strength measurements in former polio subjects. Design: HHD measurement of knee extensor strength was compared with the criterion standard of a chair dynamometer measurement in 49 subjects. The "break" method was used for HHD measurements. Reproducibility was studied for six lower extremity muscle groups in 28 subjects. The measurements were performed by one experienced and one inexperienced examiner on two separate occasions, with an interval of 1 week. The examiners were blinded to each other's and to previous results. Setting: University hospital. Subjects: Volunteer sample of former polio subjects. Results: For knee extension, the forces that could be measured with the HHD were limited to approximately 200N. Although the intraclass correlation coefficients were high (.75 to .98), the 95% limits of agreement between measurements showed large intervals for differences between two measurements (ratio intervals ranging from .76-1.52 to .52-2.77). The intraexaminer reproducibility for the experienced examiner was superior to that of the inexperienced examiner. The reproducibility of the inexperienced examiner showed systematic bias, with significantly higher strength values for the second session measurement of three muscle groups. Conclusion: The device has good validity in the lower force range. However, because the agreement between measurements was poor, it has limited ability to detect a change in muscle strength. Therefore, this method is unable to detect small changes in lower extremity muscle strength in former polio patients. (C) 1999 by the American Congress of Rehabilitation Medicine and the American Academy of Physical Medicine and Rehabilitation.
引用
收藏
页码:1316 / 1323
页数:8
相关论文
共 47 条
[1]
AGRE JC, 1991, ARCH PHYS MED REHAB, V72, P7
[2]
AGRE JC, 1987, ARCH PHYS MED REHAB, V68, P454
[3]
RELATIONSHIP OF MANUAL MUSCLE TESTING TO OBJECTIVE STRENGTH MEASUREMENTS [J].
AITKENS, S ;
LORD, J ;
BERNAUER, E ;
FOWLER, WM ;
LIEBERMAN, JS ;
BERCK, P .
MUSCLE & NERVE, 1989, 12 (03) :173-177
[4]
Normative values for isometric muscle force measurements obtained with hand-held dynamometers [J].
Andrews, AW ;
Thomas, MW ;
Bohannon, RW .
PHYSICAL THERAPY, 1996, 76 (03) :248-259
[5]
[Anonymous], 1976, Aids to the examination of the peripheral nervous system
[6]
BEASLEY W C, 1961, Arch Phys Med Rehabil, V42, P398
[7]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]
MAKE TESTS AND BREAK TESTS OF ELBOW FLEXOR MUSCLE STRENGTH [J].
BOHANNON, RW .
PHYSICAL THERAPY, 1988, 68 (02) :193-194
[9]
TEST-RETEST RELIABILITY OF HAND-HELD DYNAMOMETRY DURING A SINGLE SESSION OF STRENGTH ASSESSMENT [J].
BOHANNON, RW .
PHYSICAL THERAPY, 1986, 66 (02) :206-209
[10]
Hand-held dynamometer measurements obtained in a home environment are reliable but not correlated strongly with function [J].
Bohannon, RW .
INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 1996, 19 (04) :345-347