Mechanism for abnormal thallium-201 myocardial scintigraphy in patients with left bundle branch block in the absence of angiographic coronary artery disease

被引:20
作者
Hasegawa, S
Sakata, Y
Ishikura, F
Hirayama, A
Kusuoka, H
Nishimura, T
Kodama, K
机构
[1] Osaka Univ, Grad Sch Med D9, Biomed Res Ctr, Div Tracer Kinet, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Med 1, Suita, Osaka 5650871, Japan
[3] Osaka Police Hosp, Div Cardiovasc, Osaka, Japan
关键词
left bundle branch block; thallium; MIBI; gated SPECT;
D O I
10.1007/BF03164901
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Patients with left bundle branch block (LBBB) often show abnormal images on exercise thallium (T1)-201 scintigraphy without evidence of significant coronary stenosis. We investigated the mechanism for this phenomenon. Six patients with LBBB and without significant coronary stenosis underwent T1-201 SPECT, ECG-gated SPECT imaging with Tc-99m-methoxyisobutyl-isonitrile (MIBI), and atrial pacing stress test. The % count amplitude in Tc-99m-MIBI images was calculated as I(maximal counts) - {(minimal counts)}/(minimal counts)x 100. Though all patients had a low count in the septal and inferior wall in T1-201 SPECT images, there was no ischemic production of lactate during nn atrial pacing stress test Nevertheless gated SPECT images showed attenuated septal activity during systole. In patients with LBBB, the ratios of % count amplitude at the septum to that at the lateral wall at rest (0.47 +/- 0.05, mean +/- SE) were significantly less than the controls (n = 5, 0.83 +/- 0.12, p = 0.014). In conclusion, these results suggest that abnormal T1-201 SPECT images of the septum in patients with LBBB are partially caused by impaired septal wall thickening during systole. Such an abnormal wall motion may reduce blood flow demands to the septum, resulting in reduction of coronary blood flow with little ischemia.
引用
收藏
页码:253 / 259
页数:7
相关论文
共 18 条
  • [1] SEPTAL GLUCOSE-METABOLISM IN PATIENTS WITH CORONARY-ARTERY DISEASE AND LEFT-BUNDLE-BRANCH BLOCK
    ALTEHOEFER, C
    DAHL, JV
    BUELL, U
    [J]. CORONARY ARTERY DISEASE, 1993, 4 (06) : 569 - 572
  • [2] IMPROVED SPECIFICITY OF MYOCARDIAL TL-201 SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IN PATIENTS WITH LEFT-BUNDLE-BRANCH BLOCK BY DIPYRIDAMOLE
    BURNS, RJ
    GALLIGAN, L
    WRIGHT, LM
    LAWAND, S
    BURKE, RJ
    GLADSTONE, PJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (05) : 504 - 508
  • [3] CANNA GL, 1992, EUR HEART J, V13, P942
  • [4] COOKE CD, 1994, J NUCL MED, V35, P1185
  • [5] ECHOCARDIOGRAPHIC MANIFESTATIONS OF LEFT-BUNDLE BRANCH-BLOCK
    DILLON, JC
    CHANG, S
    FEIGENBAUM, H
    [J]. CIRCULATION, 1974, 49 (05) : 876 - 880
  • [6] Fukuchi K, 1997, J NUCL MED, V38, P1067
  • [7] TL-201 SCINTIGRAPHY IN COMPLETE LEFT-BUNDLE BRANCH-BLOCK
    HIRZEL, HO
    SENN, M
    NUESCH, K
    BUETTNER, C
    PFEIFFER, A
    HESS, OM
    KRAYENBUEHL, HP
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (06) : 764 - 769
  • [8] EXERCISE TL-201 IMAGING IN COMPLETE LEFT-BUNDLE-BRANCH BLOCK AND THE PREVALENCE OF SEPTAL PERFUSION DEFECTS
    JAZMATI, B
    SADANIANTZ, A
    EMAUS, SP
    HELLER, GV
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (01) : 46 - 49
  • [9] DIPYRIDAMOLE TL-201 SCINTIGRAPHY FOR IMPROVED DETECTION OF LEFT ANTERIOR DESCENDING CORONARY-ARTERY STENOSIS IN PATIENTS WITH LEFT-BUNDLE-BRANCH BLOCK
    JUKEMA, JW
    VANDERWALL, EE
    VANDERVISMELSEN, MJE
    KRUYSWIJK, HH
    BRUSCHKE, AVG
    [J]. EUROPEAN HEART JOURNAL, 1993, 14 (01) : 53 - 56
  • [10] KNAPP WH, 1993, EUR J NUCL MED, V20, P219