Innovative Free-Range Resonant Electrical Energy Delivery System (FREE-D System) for a Ventricular Assist Device Using Wireless Power

被引:20
作者
Waters, Benjamin H. [1 ]
Smith, Joshua R. [1 ,2 ]
Bonde, Pramod [3 ,4 ]
机构
[1] Univ Washington, Dept Elect Engn, Seattle, WA 98195 USA
[2] Univ Washington, Dept Comp Sci & Engn, Seattle, WA 98195 USA
[3] Yale Univ, Sch Med, Ctr Adv Heart Failure & Transplantat, Bonde Artificial Heart Lab, New Haven, CT 06520 USA
[4] Yale Univ, Sch Med, Ctr Adv Heart Failure & Transplantat, Sect Cardiac Surg, New Haven, CT 06520 USA
关键词
ventricular assist device; wireless power; drive-line; infection; cardiovascular implants; INFECTIONS;
D O I
10.1097/MAT.0000000000000029
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Technological innovation of a smaller, single moving part has an advantage over earlier large pulsatile ventricular assist devices (VADs) prone to mechanical failure. Drivelines limit the potential for extended patient survival durations with newer pumps and act as source for infection, increased morbidity, rehospitalizations, and reduced quality of life. The Free-range Resonant Electrical Energy Delivery (FREE-D) wireless power system uses magnetically coupled resonators to efficiently transfer power. We demonstrate the efficiency over distance of this system. The experimental setup consists of an radiofrequency amplifier and control board which drives the transmit resonator coil, and a receiver unit consisting of a resonant coil attached to a radiofrequency rectifier and power management module. The power management module supplies power to the axial pump, which was set at 9,600 rpm. To achieve a seamless wireless delivery in any room size, we introduced a third relay coil. This relay coil can be installed throughout a room, whereas a single relay coil could be built into a jacket worn by the patient, which would always be within range of the receive coil implanted in the patient's body. The power was delivered over a meter distance without interruptions or fluctuations with coil, rectifier, and regulator efficiency more than 80% and overall system efficiency of 61%. The axial pump worked well throughout the 8 hours of continuous operation. Having same setup on the opposite side can double the distance. A tether-free operation of a VAD can be achieved by FREE-D system in room-size distances. It has the potential to make the VAD therapy more acceptable from the patient perspective.
引用
收藏
页码:31 / 37
页数:7
相关论文
共 25 条
  • [1] [Anonymous], 2010, HEARTMATE 2 LVAS OPE
  • [2] [Anonymous], 2010, VENTRASSIST LVAS CLI
  • [3] Arnaoutakis GJ, 2010, CIRCULATION, V122
  • [4] Asgari S, 2013, 59 ANN C ASAIO CHI I
  • [5] Asgari SS, 2013, J THORAC CARDIOVASC, DOI [10.1016/j. jtcvs.2013.09.012., DOI 10.1016/J.JTCVS.2013.09.012.[]
  • [6] Update on Cardiovascular Implantable Electronic Device Infections and Their Management A Scientific Statement From the American Heart Association
    Baddour, Larry M.
    Epstein, Andrew E.
    Erickson, Christopher C.
    Knight, Bradley P.
    Levison, Matthew E.
    Lockhart, Peter B.
    Masoudi, Frederick A.
    Okum, Eric J.
    Wilson, Walter R.
    Beerman, Lee B.
    Bolger, Ann F.
    Estes, N. A. Mark, III
    Gewitz, Michael
    Newburger, Jane W.
    Schron, Eleanor B.
    Taubert, Kathryn A.
    [J]. CIRCULATION, 2010, 121 (03) : 458 - 477
  • [7] Bonde P, 2011, AATS 91 ANN SCI M PH
  • [8] Evaluation of Wireless Resonant Power Transfer Systems With Human Electromagnetic Exposure Limits
    Christ, Andreas
    Douglas, Mark G.
    Roman, John M.
    Cooper, Emily B.
    Sample, Alanson P.
    Waters, Benjamin H.
    Smith, Joshua R.
    Kuster, Niels
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2013, 55 (02) : 265 - 274
  • [9] Preliminary experience with the LionHeart left ventricular assist device in patients with end-stage heart failure
    El-Banayosy, A
    Arusoglu, L
    Kizner, L
    Morshuis, M
    Tenderich, G
    Pae, WE
    Körfer, R
    [J]. ANNALS OF THORACIC SURGERY, 2003, 75 (05) : 1469 - 1475
  • [10] Ventricular assist device-related infections
    Gordon, Rachel J.
    Quagliarello, Bianco
    Lowy, Franklin D.
    [J]. LANCET INFECTIOUS DISEASES, 2006, 6 (07) : 426 - 437