Analysis of 500-ng/1 levels of bromate in drinking water by direct-injection suppressed ion chromatography coupled with a single, pneumatically delivered post-column reagent

被引:44
作者
Wagner, HP
Pepich, BV
Hautman, DP
Munch, DJ
机构
[1] ICF Kaiser Environm & Facil Management Grp, Cincinnati, OH 45219 USA
[2] US EPA, Off Ground Water & Drinking Water, Cincinnati, OH 45268 USA
关键词
water analysis; derivatization; LC; bromate; inorganic anions; dianisidine;
D O I
10.1016/S0021-9673(99)00031-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In July 1997, the US Environmental Protection Agency (EPA) began sampling and analyzing drinking water matrices from US municipalities serving populations greater than 100 000 for low-level bromate (>0.20 mu g/l) in support of the Information Collection Rule (ICR) using the selective anion concentration (SAC) method. In September 1997, EPA published Method 300.1 which lowered the Method 300.0 bromate method detection limit (MDL) from 20.0 to 1.4 mu g/l This paper describes the research conducted at the EPA's Technical Support Center laboratory investigating a single post-column reagent, o-dianisidine (ODA), which has been successfully coupled to EPA Method 300.1 to extend the MDL for bromate, Initial studies indicate that this method offers a MDL which approaches the EPA's SAC method with the added benefit of increased specificity, shortened analysis time and reduced sample preparation. The method provides excellent ruggedness and acceptable precision and accuracy with a bromate MDL in reagent water of 0.1 mu g/l, and a method reporting limit of 0.50 mu g/l. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:119 / 129
页数:11
相关论文
共 34 条
[1]  
AIETA EM, 1986, J AM WATER WORKS ASS, V78, P62
[2]   OCCURRENCE OF CHLORATE IN HYPOCHLORITE SOLUTIONS USED FOR DRINKING-WATER DISINFECTION [J].
BOLYARD, M ;
FAIR, PS ;
HAUTMAN, DP .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1992, 26 (08) :1663-1665
[3]   Electrospray ion chromatography tandem mass spectrometry of oxyhalides at sub-ppb levels [J].
Charles, L ;
Pépin, D .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :353-359
[4]  
CRECELIUS EA, 1978, OZONE NEWS, V5, P1
[5]   Determination of bromate in drinking waters by ion chromatography with inductively coupled plasma mass spectrometric detection [J].
Creed, JT ;
Magnuson, ML ;
Pfaff, JD ;
Brockhoff, C .
JOURNAL OF CHROMATOGRAPHY A, 1996, 753 (02) :261-267
[6]  
*DBP ICR, 1996, EPA814B96002 DBP ICR
[7]  
*DION, 101 DION
[8]   PROCESSING DATA FOR OUTLIERS [J].
DIXON, WJ .
BIOMETRICS, 1953, 9 (01) :74-89
[9]   SPECTROPHOTOMETRIC DETERMINATION OF BROMATE IONS USING PHENOTHIAZINES [J].
FARRELL, S ;
JOA, JF ;
PACEY, GE .
ANALYTICA CHIMICA ACTA, 1995, 313 (1-2) :121-129
[10]   THE MEASUREMENT OF VERY-LOW LEVEL BROMATE ION [J].
GORDON, G ;
BUBNIS, B .
OZONE-SCIENCE & ENGINEERING, 1995, 17 (05) :551-559