Use of a mixed-mode packing and voltage tuning for peptide mixture separation in pressurized capillary electrochromatography with an ion trap storage reflectron time of flight mass spectrometer detector

被引:96
作者
Huang, PQ [1 ]
Jin, XY [1 ]
Chen, YJ [1 ]
Srinivasan, JR [1 ]
Lubman, DM [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
关键词
D O I
10.1021/ac980813u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A mixed-mode (reversed-phase/anion-exchange) stationary phase has been used as the capillary column packing for investigation of the separation of peptide mixtures in pressurized capillary electrochromatography (pCEC). This stationary phase contains both octadecylsilanes and dialkylamines. The amine groups of the stationary phase determine the charge density on the surface of the packing and can produce a strong and constant electroosmotic now (EOF) at low pH. A comparison was made in terms of the capability of separating tryptic digests between the mixed-mode phase and Cls reversed phase. In addition, the constant EOF enabled the tuning of the retention and the selectivity of the separation by adjusting the mobile phase pH from 2 to 5. Furthermore, the magnitude and the polarity of the electric voltage were demonstrated to greatly influence the elution profiles of the peptides in pCEC. An ion trap storage/reflectron time-of-flight mass spectrometer was used as an on-line detector in these experiments due to its ability to provide rapid and accurate mass detection of the sample components eluting from the separation column.
引用
收藏
页码:1786 / 1791
页数:6
相关论文
共 24 条
[1]   PRESSURIZED GRADIENT ELECTRO-HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BEHNKE, B ;
BAYER, E .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) :93-98
[2]   Capillary electrochromatography [J].
Colon, LA ;
Guo, Y ;
Fermier, A .
ANALYTICAL CHEMISTRY, 1997, 69 (15) :A461-A467
[3]   DEVELOPMENT OF AN INSTRUMENTAL CONFIGURATION FOR PSEUDO-ELECTROCHROMATOGRAPHY ELECTROSPRAY MASS-SPECTROMETRY [J].
DEKKERS, SEG ;
TJADEN, UR ;
VANDERGREEF, J .
JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (01) :201-209
[4]   Capillary electrochromatography - A high-efficiency micro-separation technique [J].
Dittmann, MM ;
Rozing, GP .
JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) :63-74
[5]  
Dittmann MM, 1997, J MICROCOLUMN SEP, V9, P399, DOI 10.1002/(SICI)1520-667X(1997)9:5<399::AID-MCS6>3.0.CO
[6]  
2-X
[7]   PRESSURIZED FLOW ELECTROCHROMATOGRAPHY WITH REVERSED-PHASE CAPILLARY COLUMNS [J].
EIMER, T ;
UNGER, KK ;
TSUDA, T .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (7-8) :649-653
[8]  
Euerby MR, 1997, J MICROCOLUMN SEP, V9, P373
[9]   Separation of tryptic digests using a modified buffer in pressurized capillary electrochromatography with an ion trap storage reflectron time-of-flight mass spectrometer [J].
Huang, PQ ;
Wu, JT ;
Lubman, DM .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :3003-3008
[10]   Capillary electrochromatography with gradient elution [J].
Huber, CG ;
Choudhary, G ;
Horvath, C .